Configuring Diagnostics
Diagnostic Settings
The IP1500/2500 speakerphone diagnostic settings are configured by:
•
Selecting
Diagnostic Settings
in the
Code Blue Configuration.
•
Click the
Enable
check box.
•
Input the
SNMP Server
IP address
and
SNMP Server Port
number to
monitor the IP1500/2500 with an
SNMP
management software or with
Code Blue’s ToolVox Gateway, with
Unit Programming & Diagnostic (UPD) Software.
•
PoE Power Failure: PoE power is the sole power source and if an interruption in service is expe
-
rienced, no Trap will be sent due to loss of PoE energy. The PoE switch should alert you to PoE
switch state.
Others – (Tests)
Microphone testing is disabled by default, and enabling will show a number of reoccurring test
routines. The microphone is supported by the speaker’s ability to generate tones at the schedule
intervals.
•
The test consists of beeps from the speaker, which will be received by the microphone.
The maximum number of beeps: 10 beeps
Once the microphone detects the beeps, the test is complete until the next scheduled test is
present.
The beep tone volume choices are soft, loud, or soft to loud.
Beep tone volume setting should be set to anticipate ambient noise level at the time of the
test.
•
The test schedule choices are:
Every 15 minutes
Hourly
Daily
Weekly
Testing on demand: When microphone speaker testing is enabled, the administrator may select to
Run Test
while logged into the IP1500/2500. The results of the test will only be present in a failed
SNMP trap, which would appear in the SNMP server logs or UPD Diagnostic Reports logs. The MIB
value is
CODEBLUE-MIB::micSpeakerFailure.