Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-162-E
page 52 of 56
Centry®
Administrator Guide
18 Maintenance Schedule
Perform functional communications check
Action: Press button
Strobe activates
Red LED “Call Placed” light turns on
Message plays
Call connects, green LED “Call Received” light turns on
Confirm conversation clarity with dispatch
Visually check lighting functions:
Faceplate light
Visually inspect unit for damage to:
Faceplate
Piezo button
Microphone
(pest infestation, damage or obstructions)
Speaker
(pest infestation, damage or obstructions)
Check batteries
Functioning with full charge
Remove faceplate assembly to inspect the following:
Ensure all electrical connections are secure
Check all phone connections for corrosion
(If corroded, clean and coat with dielectric gel or replace)
Ensure all battery connections are tight and clean
Verify no stains exist around gasket areas
(Stains indicate leaking and gasket should be replaced)
Clean and coat exterior stainless steel cabinets with cleaner/polish
(Suggested products include Chase Products'
Champion Sprayon Stainless Steel Cleaner to help protect finish against environmental pollutants)
Visually confirm line-of-sight is still clear to base station
(i.e., confirm that new tree growth, new building construction
or other obstructions are not blocking view of base station)
Guard tasks
Technician tasks
LEGEND
G
BIANNUALLY
MONTHLY OR QUARTERLY
DAILY OR WEEKLY
G
T
G
G
G
T
T
T