Centry®
Administrator Guide
7. Connect earth ground to the provided copper grounding lug using a minimum 14 gauge
conductor.
8. Connect electrical and communications wiring using the wiring diagram below.
9. Follow all federal and local codes that apply.
10. Attach faceplate to enclosure using four security screws.
1. Find both the CAT cable location and stud/mounting
structure in the wall. Mark it clearly.
2. Remove the four screws from the back box of the Centry
faceplate.
3. At the mounting location, using the back box as a guide on
the wall, mark the rough opening size.
4. Cut the required opening using available hand tools or an
electric saw.
5. Drill the mounting holes needed into your back box and
mount it to the structure.
6. Pull the CAT cable through the conduit hole in the back box.
7. Connect the CAT cable to the Ethernet port on the Centry
PCB.
8. Re-attach the Centry faceplate to its back box.
9. Screw the four faceplate screws back in place.
Vertical
Orientation