6. DOOR LOCKS
Negative Lock Output / Positive Unlock Output (GREEN)
Negative Unlock Output / Positive Lock Output (BLUE)
Negative Second Door Unlock Output (BLUE/GREEN)
Adding Aftermarket Actuators
After installing aftermarket actuators, Code Alarm part DA-1 (not supplied). Connect the GREEN and BLUE
wires shown in diagram 16 below. Use (1) Code Alarm part DLRK (Door Lock Relay Kit, not included) or
(2) Code Alarm part HDRLY (SPDT relay, not included).
30
87
87a
86
85
Fused +12 Volt
Battery Source
Door Lock
Actuator
30
87
87a
86
85
Chassis
Ground
Chassis
Ground
GREEN (-) Lock Output
BLUE (-) Unlock Output
Fused +12 Volt
Battery Source
M