Training Mode Post Dive Interval Period (10 to 30):
If the Training Mode is enabled this allows the user to
select the duration of the Post Dive Interval period
from a minimum of 10 minutes to a maximum of 30
minutes in one-minute increments. As shipped from
the factory, this is set to 10.
This option can only be
set via the Professional Edition of the Analyst
®
.
Select Clock Functions (ON or OFF):
This option
allows the diver to enable or disable the time of day
Clock. If set to ‘ON’ the clock time can also be set via
Touch Contact Programming. As shipped from the
factory, this is set to ‘OFF’.
Enter Clock Time:
This allows the diver to set the
clock’s time to that of the P.C. time.
Select Alarm Clock Audible Alarm (ON or OFF):
This option allows the diver to enable or disable the
time of day Clock’s Alarm feature. If set to ‘ON’ the
Alarm Clock time can also be set via Touch Contact
Programming. As shipped from the factory, this is set
to ‘OFF’.
Enter Alarm Clock Hour (0 to 23):
This allows the
diver to program the time of day Alarm Clock’s hour
setting. The Alarm Clock’s time utilizes a 24 hour
format, i.e. 00:00 = 12:00 am, 20:00 = 8:00 PM, etc.
This is also settable via Touch Contact Programming.
Enter Alarm Clock Minute (0 to 60):
This allows the
diver to program the time of day Alarm Clock’s minute
setting. This is also settable via Touch Contact
Programming.
Restore Original Configuration Settings:
This
allows the diver to restore the original factory default
settings with a single command.
SPECIFICATIONS:
Algorithm
16 Tissue Adaptive Modified Haldanean
Computation Period
Once every second
Activation
Manual and Water
Maximum Depth
Over 327 feet, 1 foot increments
Depth Accuracy
+/- 1% of full scale (+/- 3.3 feet)
Maximum Altitude
15,000 feet, seamless
Altitude Accuracy
+/- 1000 feet
Temperature Display
0 to 99 degrees F, 1 degree increments
Temperature Accuracy
+/- 2% of full scale (after the unit has
stabilized from a change in Temperature)
Surface Time
0 to 9:59 hrs/mins, 1-minute increments
Bottom Time
0 to 9:59 hrs/mins, 1-minute increments
Time To Fly
0 to 36 hours, 1 hour increments
No-Deco Time
0 to 9:59 hrs/mins, 1-minute increments
Decompression Time
0 to 9:59 hrs/mins, 1-minute increments
Decompression Ceiling
0 to 320 feet, 10 foot increments
Dive Summary Storage
up to 512 Dives
Dive Profile Storage
up to 550 Dive hours at one second sampling
depending on configuration
Profile Sampling
1 second increments