2
Installation
3
Moffat Cobra Series - CF4
©
Moffat Ltd, August 2012
Amendment 4
Baskets 2
Basket Trays
1
Lid 1
Drain Stick
1
Location
1. This appliance must be installed in a suitably
ventilated room to prevent dangerous build up of
combustion products.
2. Installation must allow for a sufficient flow of fresh
air for the combustion air supply.
Combustion Air Requirements
Natural Gas
24 m³/hr minimum.
LPG / Propane
24 m³/hr minimum.
Town Gas
24 m³/hr minimum.
3. Position the appliance in its approximate working
position.
4. All air for burner combustion is supplied from
underneath the appliance. The legs must always
be fitted and no obstructions placed on the
underside or around the base of the appliance, as
obstructions will cause incorrect operation and / or
failure of the appliance.
5. Components having adjustments protected (e.g.
paint sealed) by manufacturer are only allowed to
be adjusted by an qualified service agent. They
are not to be adjusted by the installation person.
NOTE:
Do not obstruct or block the appliances flue. Never
directly connect a ventilation system to the
appliance flue outlet.
Clearances
NOTE:
Only non-combustible materials can be used in
close proximity to this appliance.
In order to facilitate easy operation, drainage and
servicing of the appliance, a minimum of 600mm
clearance should be maintained at the front of the
appliance.
Any gas burning appliance requires adequate
clearance and ventilation for optimum and
trouble-free operation. The following minimum
installation clearances are to be adhered to:
Installation Requirements
NOTE:
It is most important that this appliance is
installed correctly and that operation is
correct before use. Installation shall comply
with local, gas, health and safety
requirements.
This appliance shall be installed with sufficient
ventilation to prevent the occurrence of
unacceptable concentrations of health
harmful substances in the room, the
appliance is installed in.
Blue Seal ‘FAST FRI’ gas fryers are designed to
provide years of satisfactory service and correct
installation is essential to achieve the best
performance, efficiency and trouble-free
operation.
This appliance must be installed in accordance
with National installation codes and in addition,
in
accordance with relevant National / Local
codes covering gas and fire safety.
Australia:
AS 5601- Gas Installations.
New Zealand:
NZS 5261- Gas Installation.
United Kingdom:
Gas Safety (Installation and
Use) Regulations 1998.
Ireland:
IS 820 - Non Domestic Gas
Installations.
Installations must be carried out by qualified
service persons only. Failure to install equipment
to the relevant codes and manufacturer’s
specifications shown in this section will void the
warranty.
Components having adjustments protected (e.g.
paint sealed) by manufacturer, are only to be
adjusted by an qualified service agent. They are
not to be adjusted by the installation person.
Unpacking
Remove all packaging and transit protection
from the appliance including all protective
plastic coating from the door outer panel
and exterior stainless steel panels.
Check equipment and parts for damage.
Report any damage immediately to the
carrier and distributor.
Report any deficiencies to the distributor who
supplied the appliance.
Check that the available gas supply is
correct to that shown on the rating plate
located on the inside of the access door.
Check that the following parts have been
supplied with the appliance:
Combustible
Surface
Non Combustible
Surface
LH / RH
Side
150mm
0mm
Rear
150mm
0mm