background image

INSTALLATION MANUAL 4600 CAN/PLIP

8

J-22 Positive perimetric input

:

 

to be connected to the vehicle roof lamp. The input is 7 s delayed after the system arming.

J-23 Negative input for additional modules

:

 to be used as a triggering input for the connection of compatible Cobra modules.

J-24 Analogic output

: to be used for the function described in step 7.17 or 7.20.

J-25 CDL lock negative output

: low power control signal to lock central door locking. Activated by the Cobra remote control 

(optional) - (see electrical diagram F).

J-26 Positive input for CDL motor closing signal

: to connect as indicated in the speci

fi

 c vehicle PLIP installation sheet 

or in the product installation guide for PLIP applications available on the web under Application manuals.

MAKE CONNECTIONS AS FOR ELECTRIC DIAGRAMS

6. - ACTIVE FUNCTIONALITIES.

6.1 - Interior protection with ultrasonic volumetric sensor.

The system protects the vehicle interior with a volumetric ultrasonic sensor. Any attempt to get into the vehicle will be 
detected and the alarm will trigger.

6.2 - Perimetric protection with door open warning diagnostic.

The alarm will trigger by opening any door, boot and bonnet. Should you have left any door opened while arming, the system 
will signal it by 3 

fl

 ashes of the direction lights and 3 audible signals (5 audible signals if the arming/disarming audible 

signals function has been activated).

6.3 - Cable cutting protection 

(only for systems with back-up battery siren).

The alarm will trigger if the system is not power supplied (cutting of cables - battery disconnection) signalling the sabotage. 

6.4 - Engine crank inhibition.

As soon as the system is armed the engine cranking is not possible anymore. 

 
6.5 - Arming the system with the volumetric ultrasonic protection disabled.

This function allows to arm the system leaving temporarily disconnected the interior volumetric protection. The protection 
must be disabled any time you leave somebody or an animal in the vehicle. If you want to leave any window opened also 
disable the protection to avoid false alarms. All other protections remain active. 

To disable the volumetric protection proceed as follow:

switch the engine off being sure that the ignition switch has been turned to the OFF position. Within 5 s press the emergency 
panel pushbutton and keep it pressed until it will 

fl

 ash once to con

fi

 rm only the volumetric protection has been disabled. 

By keeping the pushbutton pressed the system will con

fi

 rm with two 

fl

 ashes that only the additional sensor input has been 

disabled, with three 

fl

 ashes for both of them disabled. The selected protection will remain disabled until the system will be 

disarmed. It will be automatically restored at the next arming.

Note: 

on some vehicles the system automatically disables the volumetric protection if any windows is left opened.

6.6 - Emergency panel LED.

The LED main scope is to show the system arming and disarming conditions. When the system is armed the LED gets 
ON and remains illuminated until the 25 s arming period has elapsed. After that it starts blinking. It goes OFF as soon as 
the system is disarmed.

Summary of Contents for 4600 CAN/PLIP

Page 1: ...4600 CAN PLIP INSTALLATION MANUAL ...

Page 2: ...ations electrical connections 5 6 ACTIVE FUNCTIONALITIES descriptions 8 ELECTRIC DIAGRAMS 7 PROGRAMMABLE FUNCTIONS see the Functions programming tables manual 17 8 HOW TO PROGRAM FUNCTIONALITIES COBRA REMOTE CONTROLS AND DRIVER CARDS SELF LEARNING PROCEDURE see PAGE 1 and PAGE 2 of the Functions programming tables manual 17 9 FUNCTIONAL TEST 18 10 CAN INDEX MANUAL SELECTION 18 11 SELF LEARNING PRO...

Page 3: ...s with the negative pole connected to the vehicle body HOW TO ACCESS TO THE VEHICLE SPECIFIC TECHNICAL DOCUMENTS DATA LINKER TOOL ANTARES SOFTWARE Access to the web site www cobra at com Installer area and register yourself to be allowed to download the technical documentation Data Linker programming tool and the software Antares are required to customize the product for the destination vehicle Da...

Page 4: ...click on Application manuals to get the application manual list then download the installation manual of the 4600 for the Plip configuration 3 SYSTEM S CONFIGURATION Be sure to have connected all Data Linker components and to have power supplied the system Run Antares As soon as Antares is starting it automatically checks if the computer is connected to internet if the installed version is the mos...

Page 5: ...sources paying attention to keep the main connector oriented down Ultrasonic volumetric sensor The ultrasonic transducers must be fixed to the top of the A pillars pointed towards the rear window or to the top of the C pillars pointed towards the windscreen Their orientation should be as much as possible parallel to the side windows Emergency LED control button It must be fitted on the dashboard w...

Page 6: ...ehicle CAN installation sheet J 8 Cobra bus communication line for the connection of compatible Cobra sirens and sensors J 9 and J 10 CAN H L to connect as shown in the specific vehicle CAN installation sheet J 11 Pager negative output lowpowercontrolsignalfortriggeringapagerdeviceoratelematicone Activelowduringalarmtime J 12 CDL unlock negative output low power control signal to unlock central do...

Page 7: ...negative output lowpowercontrolsignalfortriggeringapagerdeviceoratelematicone Activelowduringalarmtime J 12 CDL unlock negative output low power control signal to unlock central door locking Activated by the Cobra remote control optional see electrical diagram F J 13 Positive input for CDL motor opening signal to connect as indicated in the specific vehicle PLIP installation sheet or in the produc...

Page 8: ...ery siren The alarm will trigger if the system is not power supplied cutting of cables battery disconnection signalling the sabotage 6 4 Engine crank inhibition As soon as the system is armed the engine cranking is not possible anymore 6 5 Arming the system with the volumetric ultrasonic protection disabled This function allows to arm the system leaving temporarily disconnected the interior volume...

Page 9: ...e diagram H 4600 Art NO WIRELESS SIREN THE FUSES IN THE DIAGRAM ARE NOT SUPPLIED BLACK RED J 15 J 14 15 A GND POWER LOGIC BLINKER HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT POWER POWER LOGIC LOGIC YELLOW YELLOW GREEN YELLOW WHITE YELLOW GREEN J 5 J 5 7 5 A J 4 7 5 A J 3 3 A J LED YELLOW BLUE J8 COBRA BUS GREEN GREEN J1 J2 max 20A 1 sec 6A cont STARTER 50 WHITE J17 SIREN H...

Page 10: ... INPUT 4600 Art WIRELESS SIREN VIOLET ORANGE J25 J12 See diagram F WHITE J17 SIREN HORN OUTPUT YELLOW BLUE J8 COBRA BUS BLUE J21 See paragraph 11 GREEN GREEN J1 J2 max 20A 1 sec 6A cont STARTER 50 PAGER OUTPUT NEGATIVE OUTPUT ARMED SYSTEM THE FUSES IN THE DIAGRAM ARE NOT SUPPLIED BLACK RED J 15 J 14 15 A GND POWER LOGIC BLINKER HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT P...

Page 11: ...D BLACK BLUE 30 See the vechicle fitting instructions 1 2 NO WIRELESS SIREN CONNECTIONS J 21 See the vechicle fitting instructions 1 2 3 A RED BLACK 30 BLUE BLACK BLACK J 8 YELLOW BLUE YELLOW BLUE BONNET PUSH BUTTON 1 14 mm Ø 10 mm Ø 2 mm 2 Ø 10 mm J H Antenna ...

Page 12: ...e Ultrasound TX and RX if you don t use the volumetric sensor A Vehicle horn connection with additional relay 87 30 86 85 Original system Additional relay Low power outputs for vehicles with negative CDL control signals Original relay controlled by a negative signal Vehicle horn connection with negative control signal to the original relay 87 30 86 85 Y P A S S T X L E D R X Y 1 2 3 U S U S 30 15A...

Page 13: ...ed to the Cobra Bus 12 flashes Immobilizer 2 module connected to the Cobra Bus 13 flashes Keyboard module connected to the Cobra Bus 14 flashes Not used 6 8 Emergency disarming If the vehicle original remote control get lost or if it doesn t work open the door with the mechanical key and turn the ignition key ON If the system doesn t disarm automatically follow the emergency procedure described in...

Page 14: ...it will go off then release it The LED starts flashing slowly a number of time corresponding to the already set index example 3 flashes for index 3 While the LED is flashing slowly press briefly the button of the emergency panel to switch to the next index each time you press the button the index increases and so on By pressing again when the last index has been selected the system will switch bac...

Page 15: ...sions 91x69x35 mm Siren dimensions 113x79x45 mm Trasmitter battery Cobra Driver Card Lithium Battery 3 V CR2032 14 FOR UK MARKET ONLY Category 1 2 or 2 1 systems permanently installed as aftermarket equipment by import or distribution centres vehicle dealers or by Independent Installers shall be installed by companies and technicians who are trained qualified industry recognised professional insta...

Page 16: ...Cobra Automotive Technologies via Astico 41 21100 VARESE ITALY www cobra at com 06DE3325C 06 12 ...