background image

INSTALLATION MANUAL 4600 CAN/PLIP

18

9. - FUNCTIONAL TEST.

During the 

fi

 rst 25 s after the system has been armed all protection functionalities can be tested without triggering an alarm.

Make the following tests during the 28 s inhibition time with the system armed:

open

 

then close one by one all doors and boot 

- Check if the system is con

fi

 rming with three audible signal, each door 

opening detection.

Check the proper functionality of the volumetric ultrasonic sensor 

- Make movements from the back seat, their detection 

will be con

fi

 rmed by a LED 

fl

 ashing.

Note

:

 

don’t check the proper functionality of the volumetric ultrasonic sensor with the windows opened as many CAN applications 

are automatically excluding this protection when the windows are left opened.

Open the bonnet then lock the vehicle with the remote control

 - While arming the system will indicate the bonnet opening 

with 3 

fl

 ashes of the direction lights and correspondingly with audible signals.This test is applicable only if the signal is detected 

from the CAN network or for systems wired siren.

Try to start the engine 

- If the engine cranking wires have been connected the engine will not start. 

Warning

: on some vehicle 

by turning the ignition key ON the system will disarm (TRANSPONDER detection).

Check if the PIN emergency Code works properly

 - By correctly entering the PIN code the system disarms.

10. - CAN / PLIP INDEX MANUAL SELECTION. 

The technical support could ask you to manually select a different CAN / PLIP index of the brand which has been loaded in 
the main unit. To select a different CAN / PLIP application (CAN INDEX) proceed as follows:

as soon as the system is powered - in the disarming state - the emergency panel LED 

fl

 ashes quickly for 5 s, during this time 

frame keep pressed the emergency panel pushbutton until it will go off then release it. The LED starts 

fl

 ashing slowly a number 

of time corresponding to the already set index (example 3 

fl

 ashes for index 3).

While the LED is 

fl

 ashing slowly, press brie

fl

 y the button of the emergency panel to switch to the next index; each time you press 

the button the index increases and so on. By pressing again when the last index has been selected the system will switch back 
to the 

fi

 rst one of the list. Select the correct CAN / PLIP index, then wait for the LED off to con

fi

 rm the current index selection.

Note1

: the same CAN index can be used for many vehicle models, check the CAN INDEX table available on the web.

Note2

: there are four PLIP index available, check the vehicle speci

fi

 c PLIP installation sheet or the PLIP application manual 

available on the web in the “Application Manuals” section. 
 

11. - 

SELF LEARNING PROCEDURE REQUIRED TO REPLACE THE MAIN UNIT OR THE WIRELESS 
SIREN REPLACEMENT.

The siren supplied in the kit is delivered already programmed to the main unit. Should you have the need to replace the siren 
or the main unit it is required to perform the self learning procedure as follows:

IMPORTANT

: don’t perform the procedure on two different vehicles parked closed each other. Their sirens could be memorized 

in one main unit only.

A.  Power the main unit by connecting the 26 ways connector.
B.  Connect the main unit blue wire to GND (only when a wireless siren is 

fi

 tted).

C.  Open the bonnet. 
D.  Connect the siren blue wire to GND (if not already grounded through the additional bonnet

 

pushbutton).

E.  Disconnect the siren 6 ways connector, then plug it again.
F.  Within 60 s turn the ignition key ON, an audible signal con

fi

 rms that the siren has been stored in the system.

G.  Turn the ignition key OFF and disconnect the BLU wires of the main unit and of the siren from GND (if grounded through 

the additional pushbutton simply open the bonnet).

Check the system functionality arming the system and triggering the alarm to check the proper sounding of the siren.

Summary of Contents for 4600 CAN/PLIP

Page 1: ...4600 CAN PLIP INSTALLATION MANUAL ...

Page 2: ...ations electrical connections 5 6 ACTIVE FUNCTIONALITIES descriptions 8 ELECTRIC DIAGRAMS 7 PROGRAMMABLE FUNCTIONS see the Functions programming tables manual 17 8 HOW TO PROGRAM FUNCTIONALITIES COBRA REMOTE CONTROLS AND DRIVER CARDS SELF LEARNING PROCEDURE see PAGE 1 and PAGE 2 of the Functions programming tables manual 17 9 FUNCTIONAL TEST 18 10 CAN INDEX MANUAL SELECTION 18 11 SELF LEARNING PRO...

Page 3: ...s with the negative pole connected to the vehicle body HOW TO ACCESS TO THE VEHICLE SPECIFIC TECHNICAL DOCUMENTS DATA LINKER TOOL ANTARES SOFTWARE Access to the web site www cobra at com Installer area and register yourself to be allowed to download the technical documentation Data Linker programming tool and the software Antares are required to customize the product for the destination vehicle Da...

Page 4: ...click on Application manuals to get the application manual list then download the installation manual of the 4600 for the Plip configuration 3 SYSTEM S CONFIGURATION Be sure to have connected all Data Linker components and to have power supplied the system Run Antares As soon as Antares is starting it automatically checks if the computer is connected to internet if the installed version is the mos...

Page 5: ...sources paying attention to keep the main connector oriented down Ultrasonic volumetric sensor The ultrasonic transducers must be fixed to the top of the A pillars pointed towards the rear window or to the top of the C pillars pointed towards the windscreen Their orientation should be as much as possible parallel to the side windows Emergency LED control button It must be fitted on the dashboard w...

Page 6: ...ehicle CAN installation sheet J 8 Cobra bus communication line for the connection of compatible Cobra sirens and sensors J 9 and J 10 CAN H L to connect as shown in the specific vehicle CAN installation sheet J 11 Pager negative output lowpowercontrolsignalfortriggeringapagerdeviceoratelematicone Activelowduringalarmtime J 12 CDL unlock negative output low power control signal to unlock central do...

Page 7: ...negative output lowpowercontrolsignalfortriggeringapagerdeviceoratelematicone Activelowduringalarmtime J 12 CDL unlock negative output low power control signal to unlock central door locking Activated by the Cobra remote control optional see electrical diagram F J 13 Positive input for CDL motor opening signal to connect as indicated in the specific vehicle PLIP installation sheet or in the produc...

Page 8: ...ery siren The alarm will trigger if the system is not power supplied cutting of cables battery disconnection signalling the sabotage 6 4 Engine crank inhibition As soon as the system is armed the engine cranking is not possible anymore 6 5 Arming the system with the volumetric ultrasonic protection disabled This function allows to arm the system leaving temporarily disconnected the interior volume...

Page 9: ...e diagram H 4600 Art NO WIRELESS SIREN THE FUSES IN THE DIAGRAM ARE NOT SUPPLIED BLACK RED J 15 J 14 15 A GND POWER LOGIC BLINKER HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT POWER POWER LOGIC LOGIC YELLOW YELLOW GREEN YELLOW WHITE YELLOW GREEN J 5 J 5 7 5 A J 4 7 5 A J 3 3 A J LED YELLOW BLUE J8 COBRA BUS GREEN GREEN J1 J2 max 20A 1 sec 6A cont STARTER 50 WHITE J17 SIREN H...

Page 10: ... INPUT 4600 Art WIRELESS SIREN VIOLET ORANGE J25 J12 See diagram F WHITE J17 SIREN HORN OUTPUT YELLOW BLUE J8 COBRA BUS BLUE J21 See paragraph 11 GREEN GREEN J1 J2 max 20A 1 sec 6A cont STARTER 50 PAGER OUTPUT NEGATIVE OUTPUT ARMED SYSTEM THE FUSES IN THE DIAGRAM ARE NOT SUPPLIED BLACK RED J 15 J 14 15 A GND POWER LOGIC BLINKER HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT P...

Page 11: ...D BLACK BLUE 30 See the vechicle fitting instructions 1 2 NO WIRELESS SIREN CONNECTIONS J 21 See the vechicle fitting instructions 1 2 3 A RED BLACK 30 BLUE BLACK BLACK J 8 YELLOW BLUE YELLOW BLUE BONNET PUSH BUTTON 1 14 mm Ø 10 mm Ø 2 mm 2 Ø 10 mm J H Antenna ...

Page 12: ...e Ultrasound TX and RX if you don t use the volumetric sensor A Vehicle horn connection with additional relay 87 30 86 85 Original system Additional relay Low power outputs for vehicles with negative CDL control signals Original relay controlled by a negative signal Vehicle horn connection with negative control signal to the original relay 87 30 86 85 Y P A S S T X L E D R X Y 1 2 3 U S U S 30 15A...

Page 13: ...ed to the Cobra Bus 12 flashes Immobilizer 2 module connected to the Cobra Bus 13 flashes Keyboard module connected to the Cobra Bus 14 flashes Not used 6 8 Emergency disarming If the vehicle original remote control get lost or if it doesn t work open the door with the mechanical key and turn the ignition key ON If the system doesn t disarm automatically follow the emergency procedure described in...

Page 14: ...it will go off then release it The LED starts flashing slowly a number of time corresponding to the already set index example 3 flashes for index 3 While the LED is flashing slowly press briefly the button of the emergency panel to switch to the next index each time you press the button the index increases and so on By pressing again when the last index has been selected the system will switch bac...

Page 15: ...sions 91x69x35 mm Siren dimensions 113x79x45 mm Trasmitter battery Cobra Driver Card Lithium Battery 3 V CR2032 14 FOR UK MARKET ONLY Category 1 2 or 2 1 systems permanently installed as aftermarket equipment by import or distribution centres vehicle dealers or by Independent Installers shall be installed by companies and technicians who are trained qualified industry recognised professional insta...

Page 16: ...Cobra Automotive Technologies via Astico 41 21100 VARESE ITALY www cobra at com 06DE3325C 06 12 ...

Reviews: