J-22 Analogic input

: make the connection if required by the speci

fi

 c vehicle CAN installation sheet.

J-23 Negative input for additional modules:

 to be used as a triggering input for the connection of compatible Cobra modules.

J-24 Analogic output

: to be used for the function described in step 7.17 or 7.20.

J-25 CDL lock negative output

: low power control signal to lock central door locking. Activated by the Cobra remote control 

(optional) - (see electrical diagram F).

J-26 Analogic input

: make the connection if required by the speci

fi

 c vehicle CAN installation sheet.

26 ways connector J pin-out for PLIP con

fi

 gurations

J-1 and J-2 Engine crank inhibition

to get the maximum security level to the system connect the two wires as shown in the 

electrical diagrams to prevent the engine starter running. During the cranking phase, measure the value of the current in the circuit that 
has been interrupt, to make sure that it does not exceed the technical speci

fi

 cations of the product. Install an additional relay if required.

J-3 Logic blinker output

:

 

make the connection if required by the speci

fi

 c vehicle PLIP installation sheet.

J-4 Power blinker output

: make the connection if required by the speci

fi

 c vehicle PLIP installation sheet.

J-5 Logic blinker feedback input or power blinker output

:

 make the connection if required by the speci

fi

 c vehicle 

PLIP installation sheet.

J-6

 

Blinker inhibition positive input

: to connect as indicated in the speci

fi

 c vehicle PLIP installation sheet or in the product 

installation guide for PLIP applications available on the web under Application manuals.

J-7 Negative input for CDL opening switch signal

: to connect as indicated in the speci

fi

 c vehicle PLIP installation sheet 

or in the product installation guide for PLIP applications available on the web under Application manuals.

J-8 Cobra BUS

communication line for the connection of compatible Cobra sirens and sensors.

J-9 and J-10 Do not connect.

J-11 Pager negative output

: low power control signal for triggering a pager device or a telematic one. Active low during alarm time.

J-12 CDL unlock negative output

: low power control signal to unlock central door locking. Activated by the Cobra remote 

control (optional) - (see electrical diagram F).

J-13 Positive input for CDL motor opening signal

: to connect as indicated in the speci

fi

 c vehicle PLIP installation sheet 

or in the product installation guide for PLIP applications available on the web under Application manuals.

J-14 12V connection (+30)

: the positive supply must be connected to a vehicle positive connection point upstream of the fuse 

box. Fit a 15A fuse as close as possible to the connection point.

J-15 GND connection

: the ground must be connected to a factory earth point or directly to the negative pole of the battery.

J-16 Negative output for modules

: active when the system is armed. To be used for the connection of compatible Cobra 

modules.

J-17 Horn/loudspeaker negative output

: to program in line with the connected device. See electric diagrams and 

functionalities programming tables. The output set automatically as per selected device, for horn choose also 

fi

 x or intermittent.

J-18 +15/54 connection

:

 to be connected to a ignition key ON positive signal. The positive signal must be feeded while starting 

the vehicle and when the engine is ON.

J-19 Negative input for CDL closing switch signal

:

 

to connect as indicated in the speci

fi

 c vehicle PLIP installation 

sheet or in the product installation guide for PLIP applications available on the web under Application manuals.

J-20 Positive perimetric input

:

 

to be connected to the vehicle roof lamp. The input is 7 s delayed after the system arming.

J-21 Negative input to enter in programming procedure/to connect bonnet pushbutton

: if connected to 

ground the system will enter in the programming procedure for all applications not able to detect the original bonnet pushbutton. If the 
siren is a wireless one this input must not be used for the bonnet pushbutton connections. For wired siren or loudspeaker this input 
must be used for the connection of the bonnet pushbutton as indicated in the speci

fi

 c vehicle PLIP installation sheet.

Summary of Contents for 4600 CAN/PLIP

Page 1: ...4600 CAN PLIP INSTALLATION MANUAL ...

Page 2: ...ations electrical connections 5 6 ACTIVE FUNCTIONALITIES descriptions 8 ELECTRIC DIAGRAMS 7 PROGRAMMABLE FUNCTIONS see the Functions programming tables manual 17 8 HOW TO PROGRAM FUNCTIONALITIES COBRA REMOTE CONTROLS AND DRIVER CARDS SELF LEARNING PROCEDURE see PAGE 1 and PAGE 2 of the Functions programming tables manual 17 9 FUNCTIONAL TEST 18 10 CAN INDEX MANUAL SELECTION 18 11 SELF LEARNING PRO...

Page 3: ...s with the negative pole connected to the vehicle body HOW TO ACCESS TO THE VEHICLE SPECIFIC TECHNICAL DOCUMENTS DATA LINKER TOOL ANTARES SOFTWARE Access to the web site www cobra at com Installer area and register yourself to be allowed to download the technical documentation Data Linker programming tool and the software Antares are required to customize the product for the destination vehicle Da...

Page 4: ...click on Application manuals to get the application manual list then download the installation manual of the 4600 for the Plip configuration 3 SYSTEM S CONFIGURATION Be sure to have connected all Data Linker components and to have power supplied the system Run Antares As soon as Antares is starting it automatically checks if the computer is connected to internet if the installed version is the mos...

Page 5: ...sources paying attention to keep the main connector oriented down Ultrasonic volumetric sensor The ultrasonic transducers must be fixed to the top of the A pillars pointed towards the rear window or to the top of the C pillars pointed towards the windscreen Their orientation should be as much as possible parallel to the side windows Emergency LED control button It must be fitted on the dashboard w...

Page 6: ...ehicle CAN installation sheet J 8 Cobra bus communication line for the connection of compatible Cobra sirens and sensors J 9 and J 10 CAN H L to connect as shown in the specific vehicle CAN installation sheet J 11 Pager negative output lowpowercontrolsignalfortriggeringapagerdeviceoratelematicone Activelowduringalarmtime J 12 CDL unlock negative output low power control signal to unlock central do...

Page 7: ...negative output lowpowercontrolsignalfortriggeringapagerdeviceoratelematicone Activelowduringalarmtime J 12 CDL unlock negative output low power control signal to unlock central door locking Activated by the Cobra remote control optional see electrical diagram F J 13 Positive input for CDL motor opening signal to connect as indicated in the specific vehicle PLIP installation sheet or in the produc...

Page 8: ...ery siren The alarm will trigger if the system is not power supplied cutting of cables battery disconnection signalling the sabotage 6 4 Engine crank inhibition As soon as the system is armed the engine cranking is not possible anymore 6 5 Arming the system with the volumetric ultrasonic protection disabled This function allows to arm the system leaving temporarily disconnected the interior volume...

Page 9: ...e diagram H 4600 Art NO WIRELESS SIREN THE FUSES IN THE DIAGRAM ARE NOT SUPPLIED BLACK RED J 15 J 14 15 A GND POWER LOGIC BLINKER HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT POWER POWER LOGIC LOGIC YELLOW YELLOW GREEN YELLOW WHITE YELLOW GREEN J 5 J 5 7 5 A J 4 7 5 A J 3 3 A J LED YELLOW BLUE J8 COBRA BUS GREEN GREEN J1 J2 max 20A 1 sec 6A cont STARTER 50 WHITE J17 SIREN H...

Page 10: ... INPUT 4600 Art WIRELESS SIREN VIOLET ORANGE J25 J12 See diagram F WHITE J17 SIREN HORN OUTPUT YELLOW BLUE J8 COBRA BUS BLUE J21 See paragraph 11 GREEN GREEN J1 J2 max 20A 1 sec 6A cont STARTER 50 PAGER OUTPUT NEGATIVE OUTPUT ARMED SYSTEM THE FUSES IN THE DIAGRAM ARE NOT SUPPLIED BLACK RED J 15 J 14 15 A GND POWER LOGIC BLINKER HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT P...

Page 11: ...D BLACK BLUE 30 See the vechicle fitting instructions 1 2 NO WIRELESS SIREN CONNECTIONS J 21 See the vechicle fitting instructions 1 2 3 A RED BLACK 30 BLUE BLACK BLACK J 8 YELLOW BLUE YELLOW BLUE BONNET PUSH BUTTON 1 14 mm Ø 10 mm Ø 2 mm 2 Ø 10 mm J H Antenna ...

Page 12: ...e Ultrasound TX and RX if you don t use the volumetric sensor A Vehicle horn connection with additional relay 87 30 86 85 Original system Additional relay Low power outputs for vehicles with negative CDL control signals Original relay controlled by a negative signal Vehicle horn connection with negative control signal to the original relay 87 30 86 85 Y P A S S T X L E D R X Y 1 2 3 U S U S 30 15A...

Page 13: ...ed to the Cobra Bus 12 flashes Immobilizer 2 module connected to the Cobra Bus 13 flashes Keyboard module connected to the Cobra Bus 14 flashes Not used 6 8 Emergency disarming If the vehicle original remote control get lost or if it doesn t work open the door with the mechanical key and turn the ignition key ON If the system doesn t disarm automatically follow the emergency procedure described in...

Page 14: ...it will go off then release it The LED starts flashing slowly a number of time corresponding to the already set index example 3 flashes for index 3 While the LED is flashing slowly press briefly the button of the emergency panel to switch to the next index each time you press the button the index increases and so on By pressing again when the last index has been selected the system will switch bac...

Page 15: ...sions 91x69x35 mm Siren dimensions 113x79x45 mm Trasmitter battery Cobra Driver Card Lithium Battery 3 V CR2032 14 FOR UK MARKET ONLY Category 1 2 or 2 1 systems permanently installed as aftermarket equipment by import or distribution centres vehicle dealers or by Independent Installers shall be installed by companies and technicians who are trained qualified industry recognised professional insta...