Nothing
Comes Close to a Cobra
®
29
28 English
Settings
VG-2 Alert
Detector is undetectable by VG-2 detection devices. An alert is given when
such a device is in use near the vehicle. When VG-2 Detect mode is On, VG-2
signals are detected and an alert given. During alert unit continues to detect
other signals. Factory setting is VG-2 Detect Off.
VG-2 Audio Mode
When VG-2 Audio mode is On, alerts are heard and displayed. This setting is
only available if VG-2 Alert is On. Factory setting is VG-2 Audio Off.
Spectre I & IV+ Alerts
Police use radar detector detectors (RDDs) to spot users of radar detectors.
Your detector is able to identify signals from
Spectre I
and
Spectre IV+
RDDs
and can provide alerts when any of these or similar devices are in use near
your vehicle.
Your detector
can
be spotted by Spectre IV+ RDDs, but is invisible to
Spectre I RDDs. You can choose whether you want to be alerted to Spectre I
& IV+ RDD signals. The factory setting is Spectre Detect Off.
Spectre Audio Mode
When
Spectre Audio
mode is on, alerts will be sounded as well as being
displayed on the screen. This setting is only available if Spectre Alert is on.
The factory setting is Spectre Audio off.
Safety Alert
When Safety Alert mode is On, Safety Alert radar signals are detected and an
alert is given. During alert unit continues to detect other signals. Factory
setting is Safety Alert On.
Low Car Voltage Warning
Many U.S. cars have continuous power to 12V outlet and if a device is
connected/kept on, it will drain vehicle’s battery. To avoid this, XRS R8/R10G
comes with SmartPower and Low Car Voltage Warning features.
The detector emits a car battery low alert when voltage drops below 11.9
volts. The detector enters SmartPower mode to avoid further battery draining.
Factory setting is Car Battery Low OFF.
Your Detector
Settings
Your Detector
Smart Power Mode
SmartPower feature turns system Off five minutes after car’s engine is turned
off. Before SmartPower engages, three beeps sound and SmartPower flashes
on display. Start the car or press Power/Pairing button to return to normal
power. Factory setting is SmartPower OFF.
Speed Indicator (Shown only if GPS Locator is connected)
Displays vehicle speed in miles per hour (MPH) or kilometers per hour
(km/h). Factory setting is MPH.
Restore Factory Settings
Restore detector to original settings here. Confirmation messages display
during process.
Pair Remote
If the MDU and RDU are not paired by wireless link, this User Settings menu
item can be used to establish the link.
Programming Alert Settings
•
POP Alert
With Pop Detect mode on, signals are detected and an alert given. During
alert unit continues to detect other signals. Factory setting is Pop Detect Off.
X Band Alert
With X Band Detect mode on, signals are detected and an alert given.
During alert unit continues to detect other signals. Factory setting is
X Band Detection On.
K Band Alert
With K Band Detect mode on, signals are detected and an alert given.
During alert unit continues to detect other signals. Factory setting is
K Band Detect On.
Ku Band Alert
With Ku Band Detect mode on, signals are detected and an alert given.
During alert unit continues to detect other signals. Factory setting is
Ku Band Detect Off.