Prepare the sensor while still on the ground: remove the large bolts holding 

the end knuckle to the mount, then use the four small bolts and lock washers 

to attach the knuckle to the sensor backplate.

Once you’re ready to mount the sensor on the pole, insert the mounting 

straps through the slots on the mount.

Position the mount on the pole at the height you chose from the table above.

Tighten the straps.

Attach the knuckle you prepared earlier to the mount using the large bolts 

(the cable connector should be pointed down). Don’t tighten completely yet, 

as you still need to align the sensor to the roadway.

www.wavetronix.com  

801.734.7200

SmartSensor HD

INSTALLATION QUICK START GUIDE

1

  Select mounting height & offset

2

  Mount the sensor

Offset

Height

(acceptable range)

6*

12

(9–19)

10 

12

(9–22)

15

15

(12–26)

20

18

(15–30)

25

26

(17–33)

30 

29

(19–37)

35 

30

(20–40)

40

33

(22–43)

45

36

(23–46)

50+

39

(25– <offset)

Offset

Height

(acceptable range)

2.0*

3.5

(2.5–5.5)

3.5

3.5

(3.0–6.0)

5.0

4.5

(3.5–8.0)

6.5

6.0

(4.5–9.5)

8.0

8.0

(5.0–10.5)

9.5

8.5

(5.5–11.5)

11.0

9.0

(6.0–12.5)

12.5

10.5

(6.5–13.5)

14.0

11.0

(7.0–14.0)

15.5+

12.0

(7.5– <offset)

Definition. 

Offset is the distance between 

the pole the sensor is mounted on and the 

edge of the first lane to be detected.

Note. 

For a more complete version of the 

table, and information about avoiding 

occlusion and multipathing, refer to the 

SmartSensor HD User Guide

.

*Reduction in number of reported speeds

Rec

ommended

3

  Align the sensor to the road

Feet

M

eters

Tilt the sensor down so the front is aimed at the center of the detection area.

If the sensor is installed on a road with an uphill/downhill grade, rotate the sensor so that the bottom edge matches the grade of 

the road (this will require the purchase of a rotating sensor backplate). 

Adjust the side-to-side angle so it’s perpendicular to the flow of traffic.

Note. 

The mounting location for your SmartSensor HD sensor(s) should have already been determined as part of the design process. If 

it has not been, please consult the 

SmartSensor HD User Guide

 for complete design and installation guidelines.