List of ADU events
98-148248-A
Appendix C: System messages
C-3
Sy
st
em mess
ag
es
0A018-0 Antenna ERROR
ISM ABS device
Cannot initialise the ISM Info:
0x00000000: Device not found (possible
cabling problem)
0x000cbbaa: Device internal error (replace
device) aa=status, bb=state, c=calibration
data error.
0A019-0 Antenna ERROR
PMM ABS device
Cannot initialise the PMM. Info: See 0A015-
0.
0A01A-0 Antenna ERROR
BCM ABS device
Cannot initialise the BCM. Info: See 0A015-0.
0A01E-0 Antenna ERROR
Sensor sanity
Too many invalid values measured by the
ISM during initialisation. Check for vibrations
or malfunctioning ISM.
0A021-0 Antenna ERROR
Azi axis calibration
Azimuth axis zero reference not found.
Check belt and zero reference module. Info:
0x00000001: Timeout (operation did not
complete in time)
0x00000010: Encoder or mechanical
problem
0x00000020: Zero reference not found
0x00000040: End stop not found.
0A022-0 Antenna ERROR
Xel axis calibration
Cross-elevation axis zero reference or end
stops not found at expected locations. Check
belt, zero reference module, and end stops.
Info: See 0A021-0.
0A023-0 Antenna ERROR
Ele axis calibration
Elevation axis zero reference or end stops not
found at expected locations. Check belt, zero
reference module, and end stops. Info: See
0A021-0.
0A025-0 Antenna ERROR
Antenna calibration
One or more errors occurred during antenna
start-up Info:
0x00000001: Timeout (calibration did not
complete in time)
0x00000010: Azimuth axis
0x00000020: Cross-elevation axis
0x00000040: Elevation axis
0x00000080: Polarisation axis
0A028-0 Antenna ERROR
Demodulator load
The second receiver demodulator cannot be
initialised and loaded correctly.
0A029-0 Antenna ERROR
XIM PLL lock
The PLL on the VIM/TIM does not lock.
Error code
(ID)
Unit
Severity
Description
Explanation
Table C-1: ADU event messages (Continued)
SAILOR600Ka-IM-98-148248.book Page 3 Monday, November 23, 2015 1:36 PM