Calibration
6-10
Chapter 6: Configuration
98-148248-A
6. Click
Apply
.
7. Switch on the modem.
Azimuth calibration with a service profile
1. Click
SERVICE > Calibration
.
2. Select the service profile in the drop down list
Satellite
. All profiles with the VSAT
modem
Service & calibration
are displayed in the list. If there is no profile in the list
see
Service profile for calibration
3. Click
Start
in the section
Azimuth calibration
and wait typically 5 minutes for the
calibration to finish. After finished calibration a message with the result of the
calibration is displayed in the field
Result
.
6.3.2
Service profile for calibration
Use this approach if you do not want to use the automatic azimuth calibration or if you
want to enter the satellite parameters directly on the calibration page. To prepare for
calibration you can set up a service profile for calibration.
To setup a service profile do as follows:
1. Connect a PC to LAN connector 3 (Service port, standard Ethernet) of the ACU or to the
front LAN connector of the ACU.
2. Open an Internet browser and enter the IP address of the ACU (Default:
http://192.168.0.1).
3. Select ADMINISTRATION and log on with User name: admin, Password: 1234
4. Select
SETTINGS > Satellite profiles
>
New entry
. Enter the name of the satellite
profile for calibration (a name of your own choice).
5. Select the modem profile
Service & calibration
from the drop-down list.
Figure 6-8: Service profile for calibration
SAILOR600Ka-IM-98-148248.book Page 10 Monday, November 23, 2015 1:36 PM