BBG-1034-AUDPRO-OM (V1.6)
BBG-1034-AUD-PRO-DSP PRODUCT MANUAL
3-67
Setup/Operating Instructions
BBG-1034-AUD-PRO-DSP Function Menu List and
Provides a global operating status and allows a log
download for factory engineering support. Also
provides controls for selecting and loading device
firmware upgrade files, and for setting the device comm
IP address.
• Device DashBoard Name Control
Allows device name In DashBoard to be changed as desired. Click return
to engage change.
• Append to Product Name appends (or adds to) existing OEM
name (for example, “BBG-1034-AUD-PRO-DSP Processing 1A”).
• Replace Product Name completely replaces the OEM name OEM
name (for example, “Processing 1A”).
Note: DashBoard instance(s) may have to be refreshed before
name change appears.
• Parameter Blast
When enabled, Parameter Blast can reduce the time it takes for the
device to appear and populate in DashBoard (this is especially relevant
where high-latency connections are present). This is facilitated by
reducing some handshakes on initial DashBoard setup where control
settings are static (not being manipulated) while the device is first
appearing.
Note: The frame network card is the arbiter of all frame/card
communications and in some cases may not accept full extent of
parameter blast under some conditions.
• Log Status and Download Controls
Admin
• Log Status indicates overall internal operating status.
• Download Log File allows an operational log file to be saved to a
host computer. This log file can be useful in case of a device error
or in the case of an operational error or condition. The file can be
submitted to Cobalt engineering for further analysis.
• Delete Log File deletes the currently displayed log file. A second
confirmation dialog is displayed to back out of the delete if desired.
• Thermal Shutdown enable/disable allows the built-in thermal
failover to be defeated. (Thermal shutdown is enabled by default).
CAUTION
The BBG-1034-AUD-PRO-DSP FPGA is designed for a normal-range
operating temperature around 85° C core temperature. Operation in
severe conditions exceeding this limit for non-sustained usage are
within device operating safe parameters, and can be allowed by
setting this control to Disable. However, the disable (override)
setting should be avoided under normal conditions to ensure
maximum device protection.
Table 3-1
BBG-1034-AUD-PRO-DSP Function Menu List — continued