BASIC INSTALLATION AND CONFIGURATION
GUIDELINES
WARNING! Qualified Technician Required for Service and
Installation
ELECTRICAL REQUIREMENTS
All self contained spas use 120VAC or 240VAC electrical
spa packs. These instructions describe the only acceptable
electrical wiring procedures. Spas wired in any other way will
void your warranty and may result in serious injury. All
installations should be completed by a certified electrician.
Failure to comply with state and local codes may result in fire
or personal injury and will be the sole responsibility of the spa
owner.
120VAC:
This requires an isolated 15 Amp circuit breaker.
This needs to be an isolated circuit with no other appliances or
lights on this circuit at any time. Extension cords are not to be
used in conjunction with the operations of the spa. Low voltage
damage could result and this is not covered by warranty.
NOTE:
All components must be 120V; No 240V
components allowable.
240VAC:
Depending on the model of spa, it will require either a
40 Amp, 50 Amp, or 60 Amp dedicated circuit breaker, GFCI,
with the proper wire size based on the length of the run. The
electrical circuit must be installed by a certified electrician and
approved by a local building or electrical inspector.
Use minimum 6AWG copper conductors only. Torque field
connections between 21 and 23 in lbs. Readily accessible
disconnecting means to be provided at time of installation.
Permanently connected power supply.
Connect only to a circuit protected by a Class A Ground Fault
Circuit Interrupter (GFCI) or Residual Current Device (RCD)
mounted at least 5’ (1.52M) from the inside walls of the spa/
Curve Spa and in line of sight from the equipment
compartment.
DISCLAIMER:
There are no user serviceable parts in the GFCI compartment. All the services and repairs should be performed by
certified electrician.
SERIES
JETS
PUMPS
VOLTAGE
AMPERAGE
FREQUENCY
CIRCUIT BREAKER
MAX FLOW RATE
Luxury
Series
65
3
x 5HP
240
4
8
60
6
0
91
Elite Series
50
1 x 4HP + 1 x 5HP
240
40
60
50
91
Luxury Series
50
1 x 4HP + 1 x 5HP
240
40
60
50
91
OPTIONAL AUXILIARY HEATER
Your spa (if opted) may be equipped with two heater
assemblies (main heater and auxiliary heater). Auxiliary heater
requires a separate 30 AMP breaker service.