22 

The Main Menu 

Time-of-Day 

Be  sure  to  set  the  Time-of-Day 

Setting  the  time-of-day  is  im-

portant  for  determining  filtration  times  and  other  background 
features. “Set Time” will appear on the display if no time-of-day 
is set in the memory. On the Settings Screen, select the Time-of
-Day  line.  On  the  Time-of-Day  screen,  simply  select  the  Hour, 
Minutes, and 12/24 Hour segments. Use the Up and Down But-
tons to make changes. 

Note: 

This only applies to some systems: If power is inter-

rupted to the system, Time-of-Day will be maintained for several 
days. 
 

Jets 

The  Spa  Screen  shows  all  available  equipment  to  control,  as 
well as other features, like Invert. The display shows icons that 
are related to the equipment installed on a particular spa model, 
so  this  screen  may  change  depending  on  the  installation.  The 
icon  buttons  are  used  to  select  and  control  individual  devices. 
Some devices, like pumps, may have more than one ON state, 
so the icon will change to reflect the state that the equipment is 
in. Below are some examples of 2-speed Pump indicators.  
If the Spa has a Circ Pump, a Circ Pump Icon will appear to indi-
cate  its  activity,  but  outside  of  Priming  Mode,  the  Circ  Pump 
cannot be controlled directly. 

Note: 

The icon for the pump that is 

associated with the heater (Circ or P1 Low) will have a red glow 
in the center when the heater is running. 
 

Settings  

The  Settings  Screen  is  where  all  programming  and  other  spa 
behaviors  are  controlled.  This  screen  has  several  features  that 
can  be  acted  on  directly.  These  features  may  include  Temp 
Range, Heat Mode, Hold, and Invert Panel. When one of these 
items  is  selected,  it  will  toggle  between  two  settings.  All  other 
menu  items  (with  an  arrow  pointing  to  the  right)  go  to  another 
level in the menu. 
 

Dual Temperature Ranges (High vs. Low) 

This  system  incorporates  two  temperature  range  settings  with 
independent set temperatures. The specific range can be select-
ed on the Settings screen and is visible on the Main Screen in 

Priming the Pumps 

As soon as the Priming Mode screen appears on the panel, se-
lect  the  “Jets  1”  button  once  to  start  Pump  1  in  low-speed  and 
then again to switch to high-speed. Also, select the other pumps, 
to turn them on. The pumps should be running in high-speed to 
facilitate  priming.  If the  pumps  have  not  primed after  2 minutes, 
and water is not flowing from the jets in the spa, do not allow the 
pumps to continue to run. Turn off the pumps and repeat the pro-
cess. Note: Turning the power off and back on again will initiate a 
new  pump  priming  session.  Sometimes  momentarily  turning  the 
pump off and on will help it to prime. Do not do this more than 5 
times. If the pump(s) will not prime, shut off the power to the spa 
and call for service. Important: A pump should not be allowed to 
run  without  priming  for more than  2 minutes.  Under  NO  circum-
stances should a pump be allowed to run without priming beyond 
the  end  of  the  4-5  minute  priming  mode.  Doing  so  may  cause 
damage to the pump and cause the system to energize the heat-
er and go into an overheat condition. 

Exiting Priming Mode 

The system will automatically enter the normal heating and filter-
ing at the end of the priming mode, which lasts 4-5 minutes. You 
can manually exit Priming Mode by pressing the  “Exit” button on 
the  Priming  Mode  Screen.  Note  that  if  you  do  not  manually  exit 
the priming mode as described above, the priming mode will be 
automatically    terminated  after  4-5  minutes.  Be  sure  that  the 
pump(s)  have  been  primed  by  this  time.  Once  the  system  has 
exited  Priming  Mode,  the  top-side  panel  will  display  the  Main 
Screen,  but  the  display  will  not  show  the  temperature  yet,  as 
shown below. This is because the system requires approximately 
1  minute  of  water  flowing  through  the  heater  to  determine  the 
water temperature and display it. 
 

Navigation 

Navigating  the  entire  menu  structure  is  done  by  touching  the 
screen. When a text item is shown in white on the main screen, it 
is selectable. The menu selections on the right side of the screen 
can  be  selected.  Select one of  these  to  enter  a  different screen 
with additional controls. Most menu screens time out and revert to 
the  main  screen  after  30  seconds  of  no  activity.  The  only  item 
that can be changed on the left side of the Main Screen is the Set 
Temperature. Touch either the set temperature line or the water 
temperature to go to the Set Temperature screen.  
 
 

Luxury Topside Quick Reference Card 

Summary of Contents for Classic Series

Page 1: ...1 ...

Page 2: ...ty Maintenance Page 9 10 MicroSilk Information Page 10 Water Clarity Troubleshooting Page 11 Product Care Guide Page 12 13 Glossary of Terms Page 13 14 Troubleshooting Guide Page 15 16 Spa Controls Page 17 22 Classic Series Controls Page 17 18 Coast Elite Series Controls Page 19 21 Coast Luxury Series Controls Page 22 23 Coast Wellness Series Controls Page 24 25 Wifi Instructions Page 26 PRV19 Ins...

Page 3: ...3 ...

Page 4: ...4 ...

Page 5: ...5 ...

Page 6: ...e consult your physician before using a hot tub Before entering the hot tub the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature regulating devices may vary as much as 5 F 2 C Persons suffering from obesity or a medical history of heart disease low or high OWNER S MANUAL 2020 blood pressure circulatory system problems or diabetes shoul...

Page 7: ... will be the sole responsibility of the spa owner 120VAC This requires an isolated 15 Amp circuit breaker This needs to be an isolated circuit with no other appliances or lights on this circuit at any time Extension cords are not to be OWNER S MANUAL 2020 used in conjunction with the operations of the spa Low voltage damage could result and this is not covered by warranty NOTE All components must ...

Page 8: ...the open position and safety cap off To completely drain the plumbing lines a wet dry shop vacu um can be used to draw out any remaining water Place the vacuum hose over the jet fittings in the spa as well as the plumbing lines in the equipment area You should also dis connect the plug on the crystal clear inspection tube if in stalled Remove the filter cartridge and store in a warm dry area Clean...

Page 9: ...icone lubricant There is a 3 8 clear line coming from the filter area and this goes to the bottom corner of the spa This drains all the water from around the filter canister This is a good time to check the skimmer basket Bring skim mer door weir forward and unscrew basket Clean out debris and reinstall Look for these specialized cleaning attachments at your local dealership WATER QUALITY MAINTENA...

Page 10: ...ll enough to enter the pores of your skin When the micro bubbles enter the pores of your skin they absorb foreign con taminants and release oxygen This process improves collagen production leaving skin feeling smooth and healthy Using the OWNER S MANUAL 2020 MicroSilk System on a regular basis greatly reduces the appear ance of wrinkles and your skin will appear younger and firmer after only a sho...

Page 11: ...o low pH is too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Cloudy Water Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water Algae Growth pH is too high Sanitizer is too low Adjust pH Shock spa with sanitize...

Page 12: ...e easily and quickly damaged when exposed to unbalanced spa water If you suspect that your chemi cals may be unbalanced remove your pillows immediately until the water has been restored to suggested conditions Do not sit on the pillows Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time yo...

Page 13: ...me when not in use to protect the shell from harmful UV rays A covered spa will use less electricity when maintaining the desired water temperature See the manual that comes with the cover for proper mount ing of the cover locks The cover should remain locked at all times to prevent unau thorized entry into the spa and potential drowning OWNER S MANUAL 2020 Do not Sit Stand or Lie on your cover No...

Page 14: ... pumping system Used while servicing the spa equipment the valves open or close the water flow to the equipment To remain open for normal use turn fully counter clockwise KNIFE VALVES A white T handled valve same functions as Gate valve see above except to open them you pull up on handle HEATER The electronically controlled heater raises the temperature of the spa to the desired setting LEDs LEDs ...

Page 15: ...Pump running constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Deal...

Page 16: ...periods of time in cold weather cold wind Hot tub is wired for 110V and jets are on Put cover back onto hot tub and allow for heat to regenerate Call your dealer if temperature does not increase Hot tubs wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No...

Page 17: ...l the high speed setting The ozone gener ator if installed will activate anytime low speed is running AUX PUMP 2 If an additional pump or blower is installed Press Aux to turn the device on If your additional device is a dual speed pump pressing Aux again will activate the pumps high speed Pressing Aux again will turn off the device pump LIGHT Press Light to operate the spa light Turns off after 4...

Page 18: ...temperature it may just be a temporary condition If flashing by itself spa is shut down If the problem persists contact your dealer or service organi zation HL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all pumps have been primed If problem persists contact your dealer or service organization LF P...

Page 19: ... power to the spa and call for service Im portant A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mode Doing so may cause damage to the pump and Continued on the next page Temperature Down Temperature Up Menu Select Light Pump Auxiliary cause the system to ene...

Page 20: ...perature FLIP UTIL INFO and FALT LOG Restricting Operation Press and release the Menu button until LOCK is on the screen Press and release the Up or Down button to enter the menu Press and release the Menu button to switch from TEMP to PANL Note Pressing and releasing the Menu button again will take you back to the beginning of the LOCK menu With TEMP or PANL selected press and release the Up or D...

Page 21: ...tory set for no address by default When set between 1 and 7 the num ber is the address See the Dolphin manual for details Utilities and Information Press and release the Menu button until UTIL appears Press and release the Up or Down button to enter the Preferences menu Use the Menu button to scroll through the options listed ahead and the Up or Down buttons to enter that section While in a sectio...

Page 22: ... speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to continue to run Turn off the pumps and repeat the pro cess Note Turning the power off and back on again will initiate a new p...

Page 23: ...her a 2 speed pump Pump 1 or a circulation pump If the heater pump is a 2 Speed Pump 1 Ready Mode will circulate water every 1 2 hour using Pump 1 Low in order to maintain a constant water tempera ture heat as needed and refresh the temperature display This is known as polling Rest Mode will only allow heating during pro grammed filter cycles Since polling does not occur the tempera ture display m...

Page 24: ... speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to continue to run Turn off the pumps and re peat the process Note Turning the power off and back on again will initiate a new pump priming session Sometimes momentari...

Page 25: ...y allow heat ing during programmed filter cycles Since polling does not oc cur the temperature display may not show a current temperature until the heater pump has been running for a minute or two When the heater pump has come on automatically for example for heating you can switch between low speed and high speed but you cannot turn the heater pump off Restricting Operation The control can be res...

Page 26: ...g Settings will open the settings menu While connected to the spa will be able to set the temperature change the de grees between F or C alter the heat mode Ready Rest select the temperature range low or high set the time of day input filter cycles time start and duration and have access to the ad vanced menu For more information on the various settings please refer to the selection in the owner s...

Page 27: ...he or button results in a search of the station and stops at next sufficient signal strength A long press results in manual tuning mode USB OPERATION A Insert a USB stick into the USB slot Songs must be of the mp3 or wma format B button Press it to pause the track Press it again to re sume play C and button Track Up Track Down Short press Track Up or Track Down button to select the next or previou...

Page 28: ...you need to synchronize the remote follow the steps below 1 Make sure Digital Media Locker is powered ON red LED the place the remote within 0 5 meter of the Digital Media Locker 2 Press and hold MODE on remote control until the LCD shows Pairing in Progress Release the button 3 Within 2 seconds the LCD will show Paired If it fails to pair the LCD will show Retry again If this happens wait 5 secon...

Page 29: ...h Multi link A second Bluetooth device can pair to the Digital Media Locker even when it has been paired to another Bluetooth device The second Blue tooth device will be able to play once the first device has stopped play ing Listening to FM Radio Press MODE on remote control to switch to FM radio mode Scan or Seek FM Radio Channels 1 Press FAST REWIND or FAST FORWARD to seek another station 2 Pre...

Page 30: ...ump 1 operation Verify that the green light on the Ozone turns on when acti vated Check the spa drain at the bottom of the spa to verify that small ozone bubbles are coming out Verify that one way check valve is installed on the ozone tubing and it is working as intended OWNER S MANUAL 2020 ...

Page 31: ... adjustment of the maintenance level Start the pump on high speed to allow water to circulate and slowly add sodium bromide uniformly in the spa by simply pouring it from the container Metric Calcula tion Add 0 143 kg of sodium bromide which has a guarantee of at least a 98 active ingredient such as BromiCharge per 100 L of water to attain 1400 ppm TDS value Total Dissolved Sol ids Example if your...

Page 32: ...32 OWNER S MANUAL 2020 ...