The appliance must be installed on a base of
incombustible material, at least 12mm thick, and to the
dimensions shown in Fig. 6.
The fire must be installed within a hearth capable of
withstanding a maximum temperature of 150
˚
C.
Conglomerate marble, marble and tiled surrounds can
meet this requirement.
The rear wall (behind the appliance) must be of
incombustible material.
The installation of the appliance must be in accordance
with the relevant requirements of the Gas Safety
(Installation and Use) Regulations 1998 (as amended),
Building Regulations and the Building Standards
(Scotland) (Consolidation) Regulations. It should be in
accordance also with any relevant requirements of the
local Gas Region and Local Authority, and the relevant
recommendations of the following current British Codes
of Practice & Standards:
BS.6891
: Installation of pipes and meters. Low pressure
installation pipes.
BS.5440
: Part 1 Flues & Part 2 Air Supply
BS.6461
: Codes of Practice for factory-made insulated
chimneys for internal application.
BS.8303
: Solid fuel appliance flue system.
In your own interests and that of safety to comply with
the law all gas appliances should be installed by
competent persons,(Corgi Registered) in accordance with
the above regulations and with these instructions. Failure
to install the appliance correctly could lead to prosecution.
INSTALLATION INSTRUCTIONS
THE LOCATION
13
DESN 512266
DESN 512268
985mm
350mm
305mm
825mm
1130mm
150mm
HEARTH
LOAD BEARING
LINTEL
FIG. 6
FIG. 7
Summary of Contents for REMBRANDT 18G/L
Page 6: ...Users Guide 5 ...
Page 12: ...Installation and Servicing Section 11 ...
Page 24: ...PLACE 5 SMALL COALS AS SHOWN DESN 512254 FIG 23 23 ...
Page 28: ...27 ...