Troubleshooting guide
The air conditioner
will not start.
• Is it plugged into a wall socket?
• Is the wall socket live?
• Does error code “P1” appear on the display? If this is the case remove the lower drain cover
(8). Make sure that all water drains out.
• The room temperature is lower than the set temperature. Adjust the temperature using [
▲
TEMP
▼
].
Insufficient cooling.
• Open windows or doors are allowing warm air in. Close all windows and doors.
• There are other sources of heat present in the room. Turn these off.
• The exhaust hose is not attached. See the
Connecting the exhaust hose
section.
• The temperature is set too high
.
Reduce the temperature.
• The air filter is clogged. See the
Care and maintenance – Cleaning the filter
section above.
Noise and vibrations
occur.
Make sure that the air conditioner is placed on a steady, even and level surface.
A gurgling sound
is heard.
This can often be explained by the movement of the coolant in the air conditioner.
This is completely normal.
Error code
E1
The temperature control sensor is out of service. Turn off the air conditioner, pull out the plug
and plug it in again. If this does not solve the problem and the error code appears again,
contact a qualified service technician.
Error code
E2
The evaporation sensor is out of service. Turn off the air conditioner, pull out the plug and plug it
in again. If this does not solve the problem and the error code appears again, contact a qualified
service technician.
Error code
E4
Incorrect or unreadable figures on the display. Turn off the air conditioner, pull out the plug and plug
it in again. If this does not solve the problem and the error code appears again, contact a qualified
service technician.
Error code
EC
(only applies to
certain models)
Coolant leakage sensor out of service. Contact a qualified service technician.
Error code
P1
The lower water tank of the air conditioner is full. Unscrew the cover of lower drain hole (8) and
ensure that all water runs out. If this does not solve the problem and the error code appears again,
contact a qualified service technician.
Note:
Error codes are shown in order of priority E4-E2-E1-P1 when several error codes are displayed at once.
Responsible disposal
This symbol indicates that this product should not be disposed of with general household waste. This applies
throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by
incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed of in
a responsible manner. When recycling your product, take it to your local collection facility or contact the place
of purchase. They will ensure that the product is disposed of in an environmentally sound manner.
Specifications
Type
Local air conditioner
Voltage
220–240 V, 50 Hz
Power
1100 W
Power input for cooling
900 W
Min room floor area
8 m²
Operating temperature
Cooling 17–35 °C (62–95 °F)
Dehumidifying 13–35 °C (55–95 °F)
Energy class
A
Capacity for cooling
8000 BTU/h
Coolant
R290 / 0,15 kg
Size
345 × 355 × 703 mm
Weight
23.5 kg