15
EN
G
LI
SH
Troubleshooting guide
The dehumidifier
will not switch on.
• Make sure that the mains lead is properly plugged in and that there
is power in the wall socket.
• The water reservoir is full or incorrectly fitted.
• The set humidity level has been reached.
The humidity is
not reducing.
• The dehumidifier has not been used long enough.
• Make sure that nothing is preventing the air in the room where
the dehumidifier is used from circulating properly.
• The humidity level is not set low enough.
• Make sure that no outdoor air can enter the room in which
the dehumidifier is being used.
• The ambient temperature is below 15 ºC.
• Is there a heat source in the room which is raising the humidity?
Unusual noises
emitted during use.
• Make sure that the air filter is clean.
• The dehumidifier is tilted or standing on an uneven surface.
Error and protection
codes (shown on
the dehumidifier’s
display)
•
AS
: Defective humidity sensor. Turn off the air conditioner, pull out
the plug and plug it in again. If this does not solve the problem,
contact a qualified service centre.
•
ES
:
Defective temperature sensor. Turn off the air conditioner,
pull out the plug and plug it in again. If this does not solve
the problem, contact a qualified service centre.
•
P1
: Automatic defrosting in progress. Let the dehumidifier be switched
on until
P1
no longer appears on the display.
•
P2
:
The water reservoir is full or incorrectly fitted. Empty of refit it.
•
E3
: Other defects. Turn off the air conditioner, pull out the plug
and plug it in again. If this does not solve the problem, contact
a qualified service centre.
Responsible disposal
This symbol indicates that this product should not be disposed of with general
household waste. This applies throughout the entire EU. In order to prevent
any harm to the environment or health hazards caused by incorrect waste
disposal, the product must be handed in for recycling so that the material can
be disposed of in a responsible manner. When recycling your product, take it to
your local collection facility or contact the place of purchase. They will ensure that
the product is disposed of in an environmentally sound manner.
Specifications
Power supply
220–240 V, 50 Hz
Power
415 W
Dehumidification capacity
Up to 20 l/day
Reservoir capacity
3 l
Operating temperature
5– 35 ºC
Coolant
R290
Size
51 × 35 × 21 cm
Weight
13 kg