LAYOUT OF BUTTONS / CONTROLS: 

 
The Aero 551 features a 1.75 x 1 inch LCD display. The display is backlit 
continuously. There is basically 1 button which can control the detector: 
The red button at the top (marked RST) is the Test/Re-set button which can 
be used to test or re-set the unit.

 

 

CO LEVEL ALARM ACTIVATION:

 

 

CO level alarm activated after: in PPM (Parts per million) 
 
PPM 

 

11 - 50  

 

Display only, No alarm 

50 – 70  

 

04 minutes 

70 - 100 

 

03 minutes 

200 

 

 

02 minutes 

300>   

 

01 minutes 

 

 

NOTE: 

Concentration of CO in air Inhalation time and toxic developed 

  

50 parts per million (ppm) Safety level as specified by the FAA  
200 PPM  Slight headache within 2-3 hours  
400 PPM  Frontal headache within 1-2 hours  
800 PPM  Dizziness, nausea, convulsions within 45 minutes 
 