C (G)-310 Main Frame Connector 

- 3 –

  

comtestnetworks.com

 

5. Grounding

5.1

 

Three methods may be used to connect the C–

310 connector to electrical ground. The connector

ground wiring is terminated at a no. 10 ground

screw terminal on the rear of the connector base

(Figure 4). This ground screw is jumpered to the

lower portion of the connector mounting bracket

through a short (3-1/2-inch) ground strap. The

grounding methods are described in the following

paragraphs.

5.2

 

Basic grounding method: 

Use the 7 3/4- 

inch interconnector ground strap supplied with the 

unit to connect the 1/4-20 mounting screws on 

adjacent connectors (see I Basic, Figure 5). 

Repeat this procedure for each pair of connectors 

on the same vertical. Connect the bottom 1/4-20 

mounting screw on the lowest connector to a 1/4- 

20 terminal on the main frame copper ground bar 

using the long (26 1/2- inch) ground strap. 

5.3

 

Independent ground method: 

Use the 

interconnector ground strap (17 1/2 inches long) to 

connect the no. 10 ground screw terminals of each 

pair of adjacent connector bases on the same 

vertical (see II Independent, Figure 5 ). Connect 

the no. 10 ground screw ground terminal on the 

lowest connector to the 1/4-20 terminal on the 

main frame copper ground bar using the long (28- 

inch) ground strap. 

5.4

 

Isolated ground method: 

Remove the short 

(3 1/2-inch) ground strap from the no. 10 screw 

ground terminal and the connector mounting 

bracket. Use the interconnector ground strap (17 

1/2-inch) to connect the no. 10 screw ground 

terminals of each pair of adjacent connector bases 

on the same vertical (see III Isolated, Figure 5). 

Connect the no. 10 screw ground terminal on the 

lowest connector to the 1/4 -20 terminal on the 

main frame copper ground bar using the long 

(28-inch) ground strap. 

Note: 

The long ground straps, 26 1/2-inch and 28- 

inch, and the interconnector ground strap, 17 1/2- 

inch, are accessory items and must be ordered 

separately. 

5.5

 

Tighten all mounting screws after all of the 

connectors and ground straps are placed in 

position on the vertical mounting bar. 

5.6

 

The clamps on the pressure plug of the 

connector stub should be carefully bent to the 

vertical mounting bar, so the stub cable will be out 

of the way for future work at the frame (Figure 6). 

5.7

 

The stub cables of all connectors on a 

vertical mounting bar should be neatly arranged 

against the transverse arms of the frame. Lash the 

stub to these transverse arms in a neat manner. 

5.8

 

Close the cable entrance slots, or ferrules, in 

the floor, in accordance with local instructions. 

Summary of Contents for C(G)-310

Page 1: ...re addresses stubbed connectors the second addresses stubless connectors 2 Description 2 1 The C G 310 connector consists of a connector base designed for installation on a main distributing frame MDF...

Page 2: ...iven in Section 6 for Changing Stub Position If there are fanning strips on the frame vertical remove them The C G 310 connector fanning strip is an integral part of the connector panel Mark the cable...

Page 3: ...connector to the 1 4 20 terminal on the main frame copper ground bar using the long 28 inch ground strap 5 4 Isolated ground method Remove the short 3 1 2 inch ground strap from the no 10 screw groun...

Page 4: ...C G 310 Main Frame Connector 4 comtestnetworks com...

Page 5: ...e molded end of the cable stub above the top of the connector base before using this method 6 1 2 Remove cable clamps from pressure plug and mounting bar 6 1 3 Turn cable stub 180 degrees 6 1 4 Reinst...

Page 6: ...ket Figure 7 Set the base aside and save screws 7 2 2 Mount the temporary mounting brackets to the mounting bracket on the frame by using the four 4 8 32 screws provided Use the small temporary mounti...

Page 7: ...C G 310 Main Frame Connector 7 comtestnetworks com...

Page 8: ...C G 310 Main Frame Connector 8 comtestnetworks com...

Page 9: ...C G 310 Main Frame Connector 9 comtestnetworks com...

Page 10: ...r grounding splicing and changing stub positions given in Sections 5 and 6 NOTES 1 Test Field 100 Tip Ring pair test receptacles 50 at top and 50 at the bottom of the connector base 2 Connector Field...

Page 11: ...the CO jumpers is on the front of the panel immediately to the right of the wire wrap terminals Each group of 10 cable pairs has two large fanning strip holes to facilitate access of the jumper wires...

Page 12: ...C G 310 Main Frame Connector 12 comtestnetworks com...

Reviews: