ENGLISH VERSION: 

Thank you for choosing a CNI-Chemodata® product. We are manufacturing Measuring, controlling, and dosing systems since 1978, Made in 
Switzerland.  
This manual will help you to understand the basics of how to correctly install, use, and maintain your new Eurodos 5 pool controller. For further 
information, more details, and technical assistance, as well as chemical background information, and detail information on water treatement in your 
pool, please contact your local installer / dealer, as these are well trained professionals, who will give you the neccessary assistance for your local 
support. 
 
 

INSTALLATION, according to Graphic 1: 

1. 

Place the system close to the pool water lines in a dry, clean area. Place the unit maintenance friendly with good access 

2. 

Connect sample water line „

1

“ from pool system, after main filter, by using a ball valve „

O

“ to flow cell input at position „

G

“,                          

use 10 mm hose (tube). Do not open valve „

O

“ yet. Suggested to drill a hole in the main pool line, then cut thread 1/2“, or 1/4“ accordingly 

3. 

Connect sample water return „

2

“ from flow cell output at position „

H

“ to pool system, after reduction valve „

3

“, by using a ball valve „

P

“,       

use 10 mm hose (tube). Do not open valve „

P

“ yet. Suggested to drill a hole in the main pool line, then cut thread 1/2“, or 1/4“ accordingly 

4. 

Install Sucction lance with red cover „

I

“ in Chlorine tank (canister) „

4

“, and connect 6 mm hose (tube) to dosing pumpe „

L

“ at inlet „

LI

“ 

5. 

Connect 6 mm hose (tube) from injection valve „

F

“ to dosing pump „

L

“ at outlet „

LO

“ 

6. 

Install Sucction lance with black cover „

K

“ in pH tank (canister) „

5

“, and connect 6 mm hose (tube) to dosing pumpe „

M

“ at inlet „

MI

“ 

7. 

Connect 6 mm hose (tube) from injection valve „

E

“ to dosing pump „

M

“ at outlet „

MO

“ 

 
We suggest to use the original „

EASY CONNECTION SET

“ for Eurodos 5, containing 10 mm hose (tube), two ball valves, two adapters, two 

connectors for easy and quick installation. Please ask your dealer for availability, if not contained. Please note: This set may, or may not be included, 
and may, or may not be available, depending on your local markets. 
 
 

FIRST RUN OF YOUR EURODOS 5 POOL CONTROLLER, according to Graphic 1: 

1. 

Switch off main pool filter pump. 

2. 

Place pH sensor with blue top at position „

A

“ into flow cell (caution: only tighten sensor by hand, do not use tools, which may cause damage 

to sensor! Warranty void if using tools!) 

3. 

Connect pH module „

C

“ with grey connector ring onto pH sensor with blue top. 

4. 

Place Redox sensor with black top at position „

B

“ into flow cell (caution: only tighten sensor by hand, do not use tools, which may cause 

damate to sensor! Warranty void if using tools!) 

5. 

Connect Redox module „

D

“ with red connector ring onto Redox sensor with black top. 

6. 

Open ball valve „

O

“, and ball valve „

P

“. Now the flow cell has connection to the pool lines. 

7. 

Slowly close reduction vlavle „

3

“ in the pool line by about 20 to 60 degrees, so that the water starts to flow in the flow cell (the use of clear 

PE tubes for the connection lines „

1

“ and „

2

“ help to see water flowing). Assure to have enaugh flow, to prevent chemical damage! 

8. 

Connect the unit to a power plug, which is switched on only when the main pool filter pump is turned on. The power plug used must been 
switched off if the main filter pump is turned off. Ask your local electric installer to help you for a correct installation

9. 

Switch on main pool filter pump, to power up the unit. 

 

 
SETTING UP YOUR EURODOS 5 FOR YOUR POOL, according to Graphic 1, and Graphic 2 (display menue structure): 

1. 

Your Eurodos 5 pool controller is simple to use. It features a colour touch screen „

N

“ to select, and set all menues and parameters. The 

simple logics is very intuitive: On touch screen „

N

“ all blue colored items are selectable, simply push, then change values, confirm with OK. 

2. 

The Eurodos 5 pool controller is pre calibrated onto the sensors, which are contained in the box. So calibration at installation, and first 
startup is not required. If original CNI-Chemodata® sensors with salt stabilizers are used, calibration is only required once at the start of the 
season / once a year, or after replacement of the sensors. For calibration, you will need buffer solutions pH7, pH9, and +465mV. Ask your 
local dealer for these items. Sensors typically last 2 years / 2 seasons. However, depending on your local water situation, sensors meight 
been at end of life anywhere from 6 month to 3 years.  

3. 

Suggested pH set point value is between 7.2 to 7.4 (factory pre set 7.4), according to your water quality. If you have very hard water, 
suggested pH set point value is 7.4, if however you have normal to soft water, suggested pH value is 7.2 

4. 

Suggested Redox (ORP) set point value is between 650 mV to 700 mV (factory pre set 650 mV), depending on the needs of your 
disinfection specific to your pool use caracteristics. Best experiences is to run you pool at normal use between 650 mV to 670 mV, which 
should be good enaugh for normal disinfection. However, if your pool is in a place surrounded by big trees, where lots of biological materials 
fall into the water, and / or heavy load of swimmers is normal (children, etc.) it is advisable to raise your Redox (ORP) value at 680 mV to 
690 mV. In very few cases, when additional temperatures of the pool water is standard to been run at 30 °C, and higher, a Redox (ORP) 
value of 700 mV could be considered as more suitable. CAUTION: DO NOT RUN YOUR POOL ON REDOX (ORP) VALUES OF 710 mV, 
OR HIGHER, TO PREVENT UNCONTROLLABLE EXCESSIVE FREE CHLORINE LEVELS IN THE WATER. 

IMPORTANT: DO NOT USE 

ANY FORM OF DRY CHEMICALS, SUCH AS CHLORINE TABS, CHLORINE TABLETS, CHLORINE POWDER, SINCE THESE 
PRODUCTS CONTAIN CYANURIC ACID, WHICH CAUSES TO BLIND OUT THE REDOX (ORP) SENSORS ABILITY TO MEASURE 
CORRECT VALUES. IF DRY CHEMICALS HAVE BEEN USED, THE ONLY WAY TO CORRECT THE SITUATION IS TO REPLACE THE 
COMPLETE POOL WATER WITH FRESH WATER. THERE IS NO OTHER SOLUTION

 

5. 

Both, pH, and Redox (ORP) dosing channels feature microdosing timers. This function is in both dosing channels in the same logics, but to 
been set up and used independantly. This function allows to slow down dosing to prevent overdosing in pools with special hydraulic 
situation, or very small pools. Set the desired dosing time (ON), and the desired waiting time (OFF). Factory pre set is 10 seconds ON, and 
10 seconds OFF. The unit will then dose in the set up cycles until the desired values of pH setpoint, and Redox (ORP) setpoints have been 
reached. If you set both, ON, and OFF timers to zero (0) seconds, you will disable microdosing, and use the unit in plain ON/OFF mode, 
without slowing down the dosing process 

6. 

Both pH, and Redox (ORP) dosing channels feature maximum sed feed timers (Max.Dose). This allows the unit to reach in each channel 
independantly the setoint values within a certain ammount of time. Factory pre set is 60 Minutes in both channels. So if the unit is not 
reaching the set point values in the preset time, the system goes in to alarm mode, and stops dosing on the affected dosing channel. You 
can reset the alarm by simply pushing on the touch screen „

N

“ the ALARM RESET field. The dosing is open again fort he pre set timing. 

7. 

The Eurodos 5 pool controller usually shows pH, and Redox (ORP) values during normal operation. A calculated indicative free chlorine 
value is shown within a certain range of pH, and ORP values. If out of range for proper calculation, the „out of range“ message shows up. 
NOTE: Free chlorine value is an indicative, calculated value only, regarding the actual pH, and Redox (ORP) situation, then showing the 
calculated value for a comparable value to your manual readings comparison, and for your convenience 

 

WE WISH YOU A GOOD SUCCESS, AND A NICE POOL SEASON. THANK YOU FOR CHOOSING A CNI-CHEMODATA® QUALITY PRODUCT.  
 
 

 
 

Summary of Contents for 1836000

Page 1: ...ational Edition Art Nr 1836000 pH Redox CNI Chemodata Eurodos 5 G2 V03 2021 Chemonorm AG Zürcherstrasse 137 CH 8852 Altendorf 41 055 451 72 22 Fax 41 055 451 72 23 Internet www chemodata com E mail info chemodata com ...

Page 2: ...Chemonorm AG Postfach 64 Zürcherstrasse 137 CH 8852 Altendorf Page 2 Grafik 1 deutsch Graphic 1 international ...

Page 3: ...te 3 Navigation im Allgemeinen Drücken Sie auf die Symbole und Texte auf dem Touch Screen Alle WEISSEN textesind Titel diese sind fix und unveränderbar Alle BLAUEN texte sind Tasten diese können gedrückt und verändert werden zur Bedienung Alle SYMBOLE sind Tasten diese können gedrückt werden zur Bedienung Falls Sie das Gerät auf die Grundeinstellungen zurücksetzen möchten gehen Sie auf Settings Za...

Page 4: ...alibration pH 7 Calibration pH 9 ORP Redox 1 Calibration 465 mV System 1 2 3 In general to navigate in system on touch screen Touch the items on the screen All WHITE texts are titles so they are fixed All BLUE texts are buttons so these you can touch and change All SYMBOLS are buttons so these you can touch to navigate If you want to set the unit back to factory preferences go to Settings top righ...

Page 5: ...21211 CNI Durchflusszelle ohne Zubehör 6 3121012 Gylon Dichtung zu Adapter 7 8601008 Anschlussnippel to 10 mm PVC 7 1 9090220 Schneidring 10 mm für Anschlussnippel 8601008 8 8601015 Doppelnippel für Anschluss Vorfilter zu Durchflusszelle 9 8601016 O Ring für Doppelnippel 10 9082001 Vorfilter komplett 11 spa 3026001 Förderschlauch P 64 0 3 l h für SPAS und SWIM SPAS bis 10 m3 auch für Easypumpen 11...

Page 6: ...n valve black 5 8421211 CNI flow cell 5 without accessories 6 3121003 O Ring sealing for connector 7 8601006 Connector to 10 mm 7 1 9090220 Cuting ring white 10 mm for connector 8601006 8 8601015 Double connector for pre filter fit to flow cell 9 8601016 O Ring for double connector 10 9082001 Pre filter complete 11 spa 3026001 Feed hose set P 64 0 3 l h for spas and small pools up to 10 m3 fits bl...

Page 7: ... oder 3026003 gem Poolgrösse bestellen Sie 2 Keine Artikel Nr 8001016 zur 0 Punkt Kalibrierung für pH Sensor bestellen Sie 1 Keine Artikel Nr 8001017 zur Steilheit Kalibrierung für pH Sensor bestellen Sie 1 Keine Artikel Nr 8001020 zur Steilheit Kalibrierung für Redox Sensor bestellen Sie 1 Wechseln benutzen zusätzlich zu den oben aufgeführten Teilen jedes zweite Jahr Pos 1 Artikel Nr 2211503 CNI ...

Page 8: ...intenance plan international Change use the following items every year season Pos 12 Item No 3026001 or 3026002 or 3026003 acccording to pool size please order 2 None Item No 8001016 to calibrate pH sensor please order 1 None Item No 8001017 to calibrate pH sensor please order 1 None Item No 8001020 to calibrate Redox sensor please order 1 Change use the following items additionally tot he above m...

Page 9: ...ur 9 Schalten Sie nun die Filterpumpe ein das Eurodos 5 erhält nun auch Strom EINSTELLUNGEN DES EURODOS 5 gemäss Grafik 1 und Grafik 2 Menü Struktur 1 Ihre Eurodos 5 ist einfach in der Anwendung Die Steuerung erfolgt über einen Touch Screen N über welchen die Navigation und alle Eingaben getätigt werden Die Bedienlogik ist intuitiv Im Touch Screen N sind alle verstellbaren Parameter blau eingefärb...

Page 10: ... change values confirm with OK 2 The Eurodos 5 pool controller is pre calibrated onto the sensors which are contained in the box So calibration at installation and first startup is not required If original CNI Chemodata sensors with salt stabilizers are used calibration is only required once at the start of the season once a year or after replacement of the sensors For calibration you will need bu...

Page 11: ...e le régulateur Eurodos 5 est aussi mis sous tension PARAMÉTRAGE DU RÉGULATEUR EURODOS 5 comme indiqué par la figure 1 et la figure 2 structure des menus 8 Votre système Eurodos 5 est facile à utiliser Il est commandé via un écran tactile N sur lequel se font la navigation et toutes les saisies La logique d utilisation est intuitive L écran tactile N affiche tous les paramètres modifiables en bleu...

Page 12: ...a is intuïtief in touchscreen N zijn alle instelbare parameters blauw gekleurd Druk eenvoudig op de waarde die moet worden aangepast wijzig de waarde vervolgens naar wens en bevestig met OK 2 Het Eurodos 5 doseersysteem is reeds voor gekalibreerd op de sensoren die in de doos zitten Dus kalibratie bij installatie of bij de eerste opstart is niet nodig Als originele CNI Chemodata sensoren met zout ...

Page 13: ...ltare l installatore elettrico locale 27 Ora accendere la pompa del filtro l Eurodos 5 riceve ora anche alimentazione IMPOSTAZIONI DELL EURODOS 5 secondo il grafico 1 e il grafico 2 struttura del menu 15 L Eurodos 5 è facile da usare Il controllo avviene tramite un touchscreen N che viene utilizzato per la navigazione e per tutti gli ingressi La logica di funzionamento è intuitiva Nel touchscreen ...

Page 14: ...no debe de llevar corriente si la bomba de filtrado está apagada Para una instalación correcta póngase en contacto con su instalador eléctrico de confianza 36 Encienda ahora la bomba de filtrado Eurodos 5 recibe ahora corriente AJUSTES DEL EURODOS 5 según el gráfico 1 y 2 Estructura del menú 22 Su Eurodos 5 es fácil de usar El control se efectúa a través de una pantalla táctil N que se utiliza par...

Page 15: ... должна находиться под напряжением при выключенном фильтр насосе Для правильной установки пожалуйста проконсультируйтесь с местным электромонтажником 45 Теперь включите фильтр насос Eurodos 5 также получит электропитание НАСТРОЙКИ EURODOS 5 в соответствии с Графиком 1 и Графиком 2 структура меню 29 Ваш Eurodos 5 прост в использовании Управление осуществляется через сенсорный экран N который исполь...

Page 16: ...ompilation of texts and pictures has been made with great care Nevertheless errors can not be completely excluded The publisher can not and will not accept any liability for incorrect information 2021 by Chemonorm AG CH 8852 Altendorf Trademarks registered to the property of Chemonorm AG Chemonorm CNI Chemodata Chemodata Eurodos Swissdos Swiss Dos Dosilogic Creapool EYE Eazydos ...

Reviews: