SAFETY PRECAUTIONS:

Please read the instructions in this column before use.
Be sure to follow the safety precaution symbols and related instructions described in
this manual. Keep this manual in case you need it.

Explanation of safety symbols and messages

When setting up this equipment

Do not expose this equipment to rain, or splashing with water or other liquids, to
avoid fire or electric shock.

This equipment can only match the voltage specified by itself, if the specified
voltage value is higher, it will cause fire or electric shock.

The power cord cannot be cut or modified to avoid damage. Avoid placing the
power cord too close to the heater; do not spill children's objects on the power
cord, including the equipment itself, to avoid fire or electric shock.

Do not install this equipment in an unstable location, so as to prevent the
equipment from falling to cause your own danger or damage to the equipment's
performance.

When using this equipment

if you find the following irregularities during use, turn off the power immediately.
If you find this situation, do not operate this equipment at will to avoid fire or
electric shock. If you smell smoke or peculiar smell from the equipment itself. If
water or any metal objects are immersed or dropped into this equipment. If the
device is dropped or the case is damaged.

If the power cord is damaged (exposed inner cord is not connected, etc.). If the
device malfunctions (no sound).

Do not drop metal or combustible objects into the ventilation slots to avoid fire
or electric shock.

Do not touch the plug or antenna during thunder and lightning to avoid fire or
electric shock.

When installing this equipment

If you want to unplug the power cord, you must hold the power plug with your
hands; do not pull directly on the power source.

Do not cover the ventilation slots on the upper cover of the device shell,
otherwise it may affect the heat dissipation of the device and cause fire.

Summary of Contents for VS-C203

Page 1: ...INSTALLATION AND OPERATION MANUAL 8 Channel Power Supply Control Unit VS C203...

Page 2: ...cause your own danger or damage to the equipment s performance When using this equipment if you find the following irregularities during use turn off the power immediately If you find this situation...

Page 3: ...control requirements of the central controller and PC but also connect various control panels to meet the supporting requirements of various systems 3 Each output normally open and normally closed ha...

Page 4: ...e panel lights up accordingly After the power is turned on the button indicator lights green Press the switch again for 2 seconds the program will turn off the power the button indicator will flash re...

Page 5: ...lock operation Keypad lock status When the indicator light of the key is red it means the machine is locked When the indicator light is green it means the machine is unlocked Unlock When the indicator...

Page 6: ...continue the program opening program closing and password modification setting operations 3 4 2 Program open settings Press the button when the indicator light is green enter the program opening sett...

Page 7: ...ic keyboard lock setting After the automatic keyboard lock is turned on the keyboard will be automatically locked after 60 seconds of no operation on the panel keys The light is red Set automatic keyb...

Page 8: ...old the button to power up the device At this time the l indicator light flashes green release the button the indicator light is steady green Color it means the factory reset is completed TECHNICAL PA...

Page 9: ...5 2 Through RS485 control and RS232 cascade control connection and external control SERIAL PROTOCOL UART Specification Baud Rate 9600 Stop Bit 1Bit...

Page 10: ...cted when reading the address Real time control WORD4 WORD5 WORD6 WORD7 address OxO xx yy yy F1 H is off FOH is on xx CH1 0X01 ch2 0x02 ch3 0x03 ch4 0x04 ch5 0x05 ch6 0x06 ch7 0X07 ch8 0x08 Timing OxO...

Page 11: ...urn status of the first pass at address 1 43 53 54 0100 00 F5 4F 4BAA Set State WORD4 WORD5 WORD6 WORD7 address DATA OxO Oxf7 DATA is the status of CH1 CH8 DATA OxFF is fully open otherwise it is full...