OPERATION AND USE:
3.1. Connect to the power supply
Connect to the power supply as required. Use RV, RVV or BV, BVV copper wires. Note:
Correctly connect according to the signs. Can not be wrong.
L----Live wire (Brown)
N----Neutral wire (Blue) G----Ground wire (Yellow green)
3.2. Switch machine operation:
When the " " indicator light is green, it means the machine is in the unlocked state.
Press the " " key for 2 seconds. When the " " indicator light is green, the program
turns on the power switches.
Channel, press the " " key again, when the " " indicator is red, the program turns
off each channel of the power supply. During the program opening/closing process,
the " " indicator flashes,
Every 1S. (Note: This operation has no program action in the factory default)
3.3. Keyboard lock operation:
Keypad lock status: When the indicator light of the "
" key is red, it means the
machine is locked. When the "
" indicator light is green, it means the machine is
unlocked. Unlock: When the indicator light of the "
" key is red, that is, when the
machine is in the locked state, press the "
" button, the indicator light of the "
"
button flashes red, in this state, use the button to enter the factory default password
"1234", If the password is entered correctly, the indicator light of the " " key will be
green, indicating that it is unlocked.
If the password is entered incorrectly, the "
" key indicator light will continue to
flash red. At this time, you can enter the password again. If the password is entered
correctly, the KEYLOCK indicator lights green, indicating that it has been unlocked.
If the password is entered incorrectly, the light of the "
" key will continue to flash
red. At this time, you can also press the "
" key to clear the input password, and