OPERATION AND USE:

3.1. Connect to the power supply

Connect to the power supply as required. Use RV, RVV or BV, BVV copper wires. Note:
Correctly connect according to the signs. Can not be wrong.

L----Live wire (Brown)

N----Neutral wire (Blue) G----Ground wire (Yellow green)

3.2. Switch machine operation:

When the " " indicator light is green, it means the machine is in the unlocked state.

Press the " " key for 2 seconds. When the " " indicator light is green, the program
turns on the power switches.

Channel, press the " " key again, when the " " indicator is red, the program turns
off each channel of the power supply. During the program opening/closing process,

the " " indicator flashes,
Every 1S. (Note: This operation has no program action in the factory default)

3.3. Keyboard lock operation:

Keypad lock status: When the indicator light of the "

" key is red, it means the

machine is locked. When the "

" indicator light is green, it means the machine is

unlocked. Unlock: When the indicator light of the "

" key is red, that is, when the

machine is in the locked state, press the "

" button, the indicator light of the "

"

button flashes red, in this state, use the button to enter the factory default password

"1234", If the password is entered correctly, the indicator light of the " " key will be
green, indicating that it is unlocked.

If the password is entered incorrectly, the "

" key indicator light will continue to

flash red. At this time, you can enter the password again. If the password is entered
correctly, the KEYLOCK indicator lights green, indicating that it has been unlocked.

If the password is entered incorrectly, the light of the "

" key will continue to flash

red. At this time, you can also press the "

" key to clear the input password, and

Summary of Contents for VS-C203

Page 1: ...INSTALLATION AND OPERATION MANUAL 8 Channel Power Supply Control Unit VS C203...

Page 2: ...cause your own danger or damage to the equipment s performance When using this equipment if you find the following irregularities during use turn off the power immediately If you find this situation...

Page 3: ...control requirements of the central controller and PC but also connect various control panels to meet the supporting requirements of various systems 3 Each output normally open and normally closed ha...

Page 4: ...e panel lights up accordingly After the power is turned on the button indicator lights green Press the switch again for 2 seconds the program will turn off the power the button indicator will flash re...

Page 5: ...lock operation Keypad lock status When the indicator light of the key is red it means the machine is locked When the indicator light is green it means the machine is unlocked Unlock When the indicator...

Page 6: ...continue the program opening program closing and password modification setting operations 3 4 2 Program open settings Press the button when the indicator light is green enter the program opening sett...

Page 7: ...ic keyboard lock setting After the automatic keyboard lock is turned on the keyboard will be automatically locked after 60 seconds of no operation on the panel keys The light is red Set automatic keyb...

Page 8: ...old the button to power up the device At this time the l indicator light flashes green release the button the indicator light is steady green Color it means the factory reset is completed TECHNICAL PA...

Page 9: ...5 2 Through RS485 control and RS232 cascade control connection and external control SERIAL PROTOCOL UART Specification Baud Rate 9600 Stop Bit 1Bit...

Page 10: ...cted when reading the address Real time control WORD4 WORD5 WORD6 WORD7 address OxO xx yy yy F1 H is off FOH is on xx CH1 0X01 ch2 0x02 ch3 0x03 ch4 0x04 ch5 0x05 ch6 0x06 ch7 0X07 ch8 0x08 Timing OxO...

Page 11: ...urn status of the first pass at address 1 43 53 54 0100 00 F5 4F 4BAA Set State WORD4 WORD5 WORD6 WORD7 address DATA OxO Oxf7 DATA is the status of CH1 CH8 DATA OxFF is fully open otherwise it is full...

Reviews: