background image

then press the "

" key to make the "

" indicator light flash in red, and enter the

password again. If you forget the password, you can press and hold the " " key, and
power on again to restore the factory default password "1234"

3.4. "

" setting operation:

In the unlocked state, long press the "

" key, release it after 3 seconds. The

"

" indicator flashes green, indicating that it has entered the setting state.

In this state, the behavior learning setting of program opening and program closing
can be performed, and the normally open channel can also be set or the password
can be modified.

3. 4. 1: Set normally open channel:

"

"When the indicator light is off, press the channel key to select the channel that

needs to be normally open. At this time, the opened channel is set as the normally
open channel, that is, after the machine is powered on,
These channels are open and are not controlled by the program switch. At this time,

press the "

" key to exit the well storage or continue the program opening,

program closing, and password modification setting operations.

3. 4. 2: Program open settings

Press the "

" button, when the "

" indicator light is green, enter the program

opening setting. If you want to start the program in the order of "1, 3, 4, 8, 7, 6, 5, 2",
You only need to open the corresponding channels in order, and the open delay is
the corresponding waiting time. The longest delay is 60 minutes, and it will
automatically exit after timeout. When setting up the program
"
When the channel is open or closed, you can remember the channel open or close

(up to 16 times). After setting, press the "

" key to exit the well and save. You can

also continue to press 3.4.3 to set the program off.

3. 4. 3: Program off setting

Press the " " key, when the " " indicator lights red, enter the program off setting.
If the program is opened, press "2, 5, 6, 7, 8, 4, 3, 1" in the order
Off, when setting the program off, you can remember that the channel is open or
closed (up to 16 times), just turn off the corresponding channels in order, and the
delay of closing is corresponding
waiting time. The longest delay is 60 minutes, and it will automatically exit after

Summary of Contents for VS-C203

Page 1: ...INSTALLATION AND OPERATION MANUAL 8 Channel Power Supply Control Unit VS C203...

Page 2: ...cause your own danger or damage to the equipment s performance When using this equipment if you find the following irregularities during use turn off the power immediately If you find this situation...

Page 3: ...control requirements of the central controller and PC but also connect various control panels to meet the supporting requirements of various systems 3 Each output normally open and normally closed ha...

Page 4: ...e panel lights up accordingly After the power is turned on the button indicator lights green Press the switch again for 2 seconds the program will turn off the power the button indicator will flash re...

Page 5: ...lock operation Keypad lock status When the indicator light of the key is red it means the machine is locked When the indicator light is green it means the machine is unlocked Unlock When the indicator...

Page 6: ...continue the program opening program closing and password modification setting operations 3 4 2 Program open settings Press the button when the indicator light is green enter the program opening sett...

Page 7: ...ic keyboard lock setting After the automatic keyboard lock is turned on the keyboard will be automatically locked after 60 seconds of no operation on the panel keys The light is red Set automatic keyb...

Page 8: ...old the button to power up the device At this time the l indicator light flashes green release the button the indicator light is steady green Color it means the factory reset is completed TECHNICAL PA...

Page 9: ...5 2 Through RS485 control and RS232 cascade control connection and external control SERIAL PROTOCOL UART Specification Baud Rate 9600 Stop Bit 1Bit...

Page 10: ...cted when reading the address Real time control WORD4 WORD5 WORD6 WORD7 address OxO xx yy yy F1 H is off FOH is on xx CH1 0X01 ch2 0x02 ch3 0x03 ch4 0x04 ch5 0x05 ch6 0x06 ch7 0X07 ch8 0x08 Timing OxO...

Page 11: ...urn status of the first pass at address 1 43 53 54 0100 00 F5 4F 4BAA Set State WORD4 WORD5 WORD6 WORD7 address DATA OxO Oxf7 DATA is the status of CH1 CH8 DATA OxFF is fully open otherwise it is full...

Reviews: