READ AND FOLLOW ALL INSTRUCTIONS

•  Read this manual completely before attempting installation. Failure to install in accordance with the installation 

instructions could void warranty and result in injury or death.

•  All permanent electrical connections should be made by a qualified electrician.

•  A pressure wire connector, labeled “bonding lugs”, is provided on the outside of the unit to permit connection to 

a minimum No. 6 AWG (13.3 mm2) solid bonding conductor between this point and any metal equipment, metal 

enclosures of electrical equipment, metal water pipes, or conduit within 5 feet (1.5 meters) of the unit as needed to 

comply with local requirements.

•  Install at least 5 feet (1.5 meters) from wall of pool.

•  Follow all applicable electrical codes.

• 

DANGER

ELECTRIC SHOCK HAZARD: 

Be sure to turn power OFF and disconnect from power source before 

any service work is performed. Failure to do so could result in serious injury or death.

•  The UV-C Pro must be installed in an outdoor location, or indoors in a forced air ventilated room, and installed so 

that the orientation is exactly as shown in Figure 3. Install to provide water drainage of generator to protect electrical 

components.

•  Mount the UV-C Pro so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit is wet.

•  For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors near this or any other 

appliance.

•  To maintain cosmetic integrity, protect this unit from direct prolonged sunlight exposure.

•  To reduce the risk of injury, do not permit children to use this product, unless they are closely supervised at all times.

•  ENVIRONMENTAL NOTICE:

 Hg-Lamp CONTAINS MERCURY. Manage in accordance with disposal laws.  

See: www.lamprecycle.org

•  If unit is not operated according to instructions, high dosages of harmful substances may potentially be released.

•  Product has met the requirement of NSF/ANSI 50, Annex H.1 for supplemental disinfection and is designed for pools 

that are in compliance with the U.S. Model Aquatic Health Code (MAHC).  Installed flow rates must not exceed max 

listed flow rates to maintain NSF product listing as well as ensuring proper microbial performance.

•  NSF/ANSI 50, Section 13 disinfection efficacy testing for 3 log (99.9%) or greater of Pseudomonas Aeruginosa and 

Enterococcus Faecium.  Specific residual levels of EPA registered disinfection chemicals may be required by the 

regulatory agency having authority.  Product is designed for supplemental disinfection and should be used with 

registered or approved disinfection chemicals to impart residual concentrations.

SAVE THESE INSTRUCTIONS!

IMPORTANT INFORMATION

Summary of Contents for DEL AOP PRO 200

Page 1: ...4 2813 01 Rev A CMPCOMMERCIAL COM DEL UV C PRO 200 350 500 INSTALLATION INSTRUCTIONS PRODUCT MANUAL...

Page 2: ...ssible to anyone in the pool Never attempt any servicing while unit is wet For your safety do not store or use gasoline chemicals or other flammable liquids or vapors near this or any other appliance...

Page 3: ...on 4 3C System Shut Down 6 3D Water Chemistry 6 4 Maintenance Service 4A System Electromechanical Overview 7 4B UV Reactor Service and Maintenance 7 4C PLC Memory Battery Backup Replacement 10 4D Wint...

Page 4: ...esults UV C is compatible with all traditional sanitizers These systems are cost effective to operate and maintain UV C Pro is NSF certified for supplemental disinfection of pools and spas UV C PRO 20...

Page 5: ...a protected from rain and direct sunlight Locate the unit out of reach of sprinklers or drainage spouts Allow sufficient access for maintenance 2 ft clearance above and 1 ft around the unit and all pl...

Page 6: ...to an external device that closes when the pool pump is ON and opens when it is OFF Failure to use the remote start contacts may result in damage to the unit not covered under warranty 2E Plumbing The...

Page 7: ...screen includes status indicators and text to communicate real time system conditions as well as access to historical data The five function buttons allow user navigation of the menus and user input T...

Page 8: ...lert reminders More than 10 remaining no banner message 10 remaining SERVICE SOON banner message 5 remaining SERVICE REQUIRED banner message 0 remaining SERVICE PAST DUE alert banner message with yell...

Page 9: ...Followed for servicing or storage 1 Shut off water flow to the unit and or close isolation valves if available 2 Shut off power at the breaker 3 Open enclosure door to access internal components NOTE...

Page 10: ...p is difficult to remove use a slight twisting motion or remove the lamp retainer AVOID TOUCHING THE UV LAMP GLASS WITH YOUR BARE HANDS Oils on your hands can cause hot spots on the UV lamp and shorte...

Page 11: ...8 4 MAINTENANCE SERVICE Inlet Flange Outlet Flange Flow Switch Location not shown Ballast UV Reactor Figure 3 UV C Pro Electro Mechanical Overview...

Page 12: ...emoval Figure 5 UV Quartz Tube lnstallation NOTE DAMAGES CAUSED BY BROKEN QUARTZ TUBES ARE NOT COVERED UNDER THE LIMITED WARRANTY UV Lamp Quartz Tube Lamp Retainer Sealing O ring Lamp Retainer Screws...

Page 13: ...tom of the quartz tube 3 Connect the UV lamp connector to the connector on the ballast ENVIRONMENTAL NOTICE Hg Lamp CONTAINS MERCURY Manage in accordance with disposal laws See www lamprecycle org Fig...

Page 14: ...box b Check for loose connections or wiring breaks in the main power wiring leading to the UV C Pro c Check internal circuit breaker Symptom SYSTEM WAITING ON REMOTE START CONTACTS message 1 Remote s...

Page 15: ...u call 1 800 733 9060 or visit www cmpcommercial com 5D Standard Replacement Parts List DESCRIPTION PART NUMBER REPLACEMENT INTERVAL PLC MEMORY BACKUP BATTERY included with PLC option only 5 1402 Annu...

Page 16: ...Pro Pressure Drop Characterization NOTE Tested on simulated recirculation system using a variable speed pump No back pressure added Actual results will vary depending on pump and plumbing variables AP...

Page 17: ...utlet unions or flanges b Flow the cleaning solution from bottom to top 2 When cleaning is complete drain the UV C Pro completely from the inlet union or flange and run the pool system immediately for...

Page 18: ...Below Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date __________...

Page 19: ...16 NOTES...

Page 20: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW CMPCOMMERCIAL COM 1021ab...