Rev. A  1-17-02

1

P/N  472063

ELECTRICAL, for MiniMax NT 120 SINGLE VOLTAGE Heaters

Electrical Rating

50/60 Hz

120 V.A.C. ONLY

NOTE

The transformer is pre-wired at the factory for 120 VAC operation ,connect line supply to the line
terminal block inside junction box. Use caution in connecting supply to proper Line (L), Neutral (N),
and Ground (GND) terminals; see below, Figure 1.

NOTE

If any of the original wiring supplied with this heater must be replaced, installer must supply

(No. 18 AWG 105° C. U.L. approved AWM low energy stranded) copper wire or it’s equivalent.

WARNING

The heater must be electrically grounded and bonded in accordance with local codes or, in the absence
of local codes, with the latest national electrical codes ANSI/NFPA No. 70.

LINE TERMINAL BLOCK

Figure 2.

1

2

3

POOL

SPA

GND

REMOTE HOOK-UP

Before connecting the remote control system please read the following:

1. First turn the gas valve to the "OFF" position and power up the heater,

now using the front buttons on the temperature controller,  set the "SPA"
and "POOL" temperature to the maximum setting.

2. Now turn the heater to the "OFF" mode by using the "OFF" button on

the temperature controller, by using the main power switch located on
the bottom of the junction box.

3. With the heater in the "OFF" mode, locate the three tabs on the back of

the temperature controller as viewed from the backside, see Figure 2.

Pentair Pool Products

1620 Hawkins Ave., Sanford, NC 27330  •  (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021  •  (805) 523-2400

L

N

GREEN WIRE

WHITE WIRE

BLACK WIRE

GROUND
CONNECTION

NEUTRAL / WHITE 120 VAC

POSITIVE LINE FOR 120 VOLTS AC

INTERNAL
FACTORY WIRES

Figure 1.