5B.  Contact Information:

For technical assistance:

•  Call: 1-800-733-9060

•  Email: [email protected]

•  Visit: www.cmpcommercial.com

Be prepared with the following information:

•  Name

•  Address

•  Model #

•  Date Purchased

5C.  Ordering Information:

To locate a dealer nearest you call 1-800-733-9060 or visit www.cmpcommercial.com.

5D. Standard Replacement Parts List

DESCRIPTION

PART NUMBER

REPLACEMENT INTERVAL

PLC MEMORY BACKUP BATTERY

(included with PLC option only)

5-1402

Annually

UV LAMP REPLACEMENT KIT

9-1226-01 (EA)

16,000 Hours

QUARTZ TUBE REPLACEMENT KIT

9-1701-01 (EA)

As Needed

Table 2: Replacement Parts

NOTE: 

The warranty is void if the parts listed above are not replaced at recommended intervals. 

5. TROUBLESHOOTING & RESOURCES

Summary of Contents for DEL AOP PRO 200

Page 1: ...4 2813 01 Rev A CMPCOMMERCIAL COM DEL UV C PRO 200 350 500 INSTALLATION INSTRUCTIONS PRODUCT MANUAL...

Page 2: ...ssible to anyone in the pool Never attempt any servicing while unit is wet For your safety do not store or use gasoline chemicals or other flammable liquids or vapors near this or any other appliance...

Page 3: ...on 4 3C System Shut Down 6 3D Water Chemistry 6 4 Maintenance Service 4A System Electromechanical Overview 7 4B UV Reactor Service and Maintenance 7 4C PLC Memory Battery Backup Replacement 10 4D Wint...

Page 4: ...esults UV C is compatible with all traditional sanitizers These systems are cost effective to operate and maintain UV C Pro is NSF certified for supplemental disinfection of pools and spas UV C PRO 20...

Page 5: ...a protected from rain and direct sunlight Locate the unit out of reach of sprinklers or drainage spouts Allow sufficient access for maintenance 2 ft clearance above and 1 ft around the unit and all pl...

Page 6: ...to an external device that closes when the pool pump is ON and opens when it is OFF Failure to use the remote start contacts may result in damage to the unit not covered under warranty 2E Plumbing The...

Page 7: ...screen includes status indicators and text to communicate real time system conditions as well as access to historical data The five function buttons allow user navigation of the menus and user input T...

Page 8: ...lert reminders More than 10 remaining no banner message 10 remaining SERVICE SOON banner message 5 remaining SERVICE REQUIRED banner message 0 remaining SERVICE PAST DUE alert banner message with yell...

Page 9: ...Followed for servicing or storage 1 Shut off water flow to the unit and or close isolation valves if available 2 Shut off power at the breaker 3 Open enclosure door to access internal components NOTE...

Page 10: ...p is difficult to remove use a slight twisting motion or remove the lamp retainer AVOID TOUCHING THE UV LAMP GLASS WITH YOUR BARE HANDS Oils on your hands can cause hot spots on the UV lamp and shorte...

Page 11: ...8 4 MAINTENANCE SERVICE Inlet Flange Outlet Flange Flow Switch Location not shown Ballast UV Reactor Figure 3 UV C Pro Electro Mechanical Overview...

Page 12: ...emoval Figure 5 UV Quartz Tube lnstallation NOTE DAMAGES CAUSED BY BROKEN QUARTZ TUBES ARE NOT COVERED UNDER THE LIMITED WARRANTY UV Lamp Quartz Tube Lamp Retainer Sealing O ring Lamp Retainer Screws...

Page 13: ...tom of the quartz tube 3 Connect the UV lamp connector to the connector on the ballast ENVIRONMENTAL NOTICE Hg Lamp CONTAINS MERCURY Manage in accordance with disposal laws See www lamprecycle org Fig...

Page 14: ...box b Check for loose connections or wiring breaks in the main power wiring leading to the UV C Pro c Check internal circuit breaker Symptom SYSTEM WAITING ON REMOTE START CONTACTS message 1 Remote s...

Page 15: ...u call 1 800 733 9060 or visit www cmpcommercial com 5D Standard Replacement Parts List DESCRIPTION PART NUMBER REPLACEMENT INTERVAL PLC MEMORY BACKUP BATTERY included with PLC option only 5 1402 Annu...

Page 16: ...Pro Pressure Drop Characterization NOTE Tested on simulated recirculation system using a variable speed pump No back pressure added Actual results will vary depending on pump and plumbing variables AP...

Page 17: ...utlet unions or flanges b Flow the cleaning solution from bottom to top 2 When cleaning is complete drain the UV C Pro completely from the inlet union or flange and run the pool system immediately for...

Page 18: ...Below Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date __________...

Page 19: ...16 NOTES...

Page 20: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW CMPCOMMERCIAL COM 1021ab...

Reviews: