Risks caused by vibrations
The vibration values specified in the technical data
represent the main uses of the device. The actual
existing vibrations during use may deviate from these
as a result of the following factors:
• Incorrect use of the product;
• Unsuitable tools inserted;
• Unsuitable material;
• Insufficient maintenance.
You can reduce the risks considerably by following
the tips below:
– Maintain the device in accordance with the
instructions in the operating instructions.
– Avoid working at low temperatures.
– When it is cold, make sure your body and your
hands, in particular, are kept warm.
– Take regular breaks and move your hands at the
same time to promote circulation.
Personal safety equipment
Your machine at a glance
1.
On-Off switch
2.
Safety lock
3.
Additional handle
4.
Protective hood for grinding
5.
Abrading disc
6.
Clamping screw for protective hood
7.
Locking button for spindle
What is included
• Angle grinder
• Protective hood for grinding
• Additional handle
• Face pin wrench for fitting abrading disc
• Carbon brushes (2×)
• Instructions for use
Fitting
Fit the additional handle
The additional handle can be attached on the left [1],
at the top [2] or on the right [3] of the product.
– Screw the additional hand grip firmly into the
threaded hole on the appliance.
Permissible grinding tools
• The permissible maximum rpm or cutting speed
of the abrasive bodies used must comply with the
details in the table below.
• Therefore please observe the permissible rpm or
peripheral speed on the label of the abrasive
body.
• Always use the intermediate layers enclosed with
the abrasive bodies: they are positioned between
the abrasive body and the clamping flange and
must be at least the same size as the contact sur-
faces of the flanges.
• When using abrasive bodies with threaded
inserts, it must be ensured that the end of the
spindle never touches the perforated plate of the
grinding tool (spindle length:
• Abrasive bodies with threaded insert must be
able to be screwed onto the grinding spindle far
enough that they firmly fit the grinding spindle
flange at the end of the grinding spindle thread.
CAUTION! Risk of injury due to vibra-
tions!
Vibrations may, in particular for per-
sons with circulation problems, cause dam-
age to blood vessels and/or nerves.
If you notice any of the following symptoms,
stop working immediately and consult a doc-
tor. Numbness of body parts, loss of sense of
feeling, itching, pins and needles, pain,
changes in skin colour.
Wear goggles when working with the de-
vice.
Wear ear defenders when working with the
device.
When working with tools that cause consid-
erable dust, wear a dust protection mask.
Do not wear protective gloves when work-
ing with the device.
Wear tight fitting clothes when working with
the device.
If you have long hair, cover or wear a hair
net.
Dimensions
D
b
d
Max. rpm
max. cutting speed
180 mm
6 mm
22,2 mm
8500 min-1
80 m/s
230 mm
6 mm
22,2 mm
6500 min-1
80 m/s
180 mm
—
—
8500 min-1
80 m/s
230 mm
—
—
6500 min-1
80 m/s
b
d
D
D
Summary of Contents for C-WIS-2000/230 H
Page 3: ...3 1 6 7 2 1 3 4 5 3 2 1 2 8 2 1 3 ...
Page 4: ...4 1 2 4 ...
Page 13: ...DE 13 Ersatzteile Ersatzteile sind bei Ihrem Händler erhältlich ...
Page 22: ...IT 22 Ricambi I ricambi sono disponibili presso il vostro rivendi tore ...
Page 115: ...NL 115 Reserveonderdelen Reserveonderdelen zijn bij uw verkoper verkrijg baar ...
Page 150: ...150 ...
Page 151: ...151 ...
Page 152: ...Art Nr 234881 V 010921 Emil Lux GmbH Co KG Emil Lux Straße 1 42929 Wermelskirchen GERMANY ...