Emergency operations
4.5.1
Emergency button
In case of emergency , push the emergency button 2 (Picture 9) and 8
(Picture 7) pushing this button (with mechanical blocking device) the
MEWP thermal or electrical engine stalls and all operations are disabled.
To reset the normal working conditions, rotate this button clockwise.
4.5.2
Platform controls (emergency) station
In case of emergency, the controls of the MEWP aerial part can be operat-
ed by the ground operator, by using the “Platform controls (emergency) sta-
tion” described in par.3.3.2. This station can be operated by turning in verti-
cal position the key clockwise 1 (Picture 23).
Picture 23: emergency station closing carter
4.5.3
Hand pump (hydraulic system failure)
In case of emergency (fuel exhaustion etc.) to get the pressure inside the
hydraulic circuit, necessary for the functioning of the MEWP components, it
is possible to use the hand pump 1 (
Picture 24
).
Picture 24: hand pump
First close the platform by unfastening the hydraulic handle 2 (
Picture 24
)
near the hydraulic seat in picture and start closing the MEWP.
1
2
3
1
4
Summary of Contents for SUP15
Page 8: ...MAN 161 rev 5 Use and maintenance manual Sup15 8ª page of 77 Picture 4 stabilization area mm ...
Page 70: ...MAN 161 rev 5 Use and maintenance manual Sup15 70ª page of 77 10 10 Notes ...
Page 72: ...MAN 161 rev 5 Use and maintenance manual Sup15 72ª page of 77 ...
Page 73: ...MAN 161 rev 5 Use and maintenance manual Sup15 73ª page of 77 ...
Page 74: ...MAN 161 rev 5 Use and maintenance manual Sup15 74ª page of 77 ...
Page 75: ...MAN 161 rev 5 Use and maintenance manual Sup15 75ª page of 77 ...
Page 76: ...MAN 161 rev 5 Use and maintenance manual Sup15 76ª page of 77 ...