4.2
Approach distances for qualified employees – Al-
ternating current
Voltage range (phase to phase) / Minimum approach dis-
tance
300 V and less / Avoid Contact
Over 300 V, not over 750 V / 1 ft. 0 in. (30.5cm),
Over 750 V, not over 2 kV / 1 ft. 6 in. (46 cm),
Over 2 kV, not over 15 kV / 2 ft. 0 in. (61 cm),
Over 15 kV, not over 37 kV / 3 ft. 0 in. (91 cm),
Over 37 kV, not over 87.5 kV / 3 ft. 6 in. (107 cm),
Over 87.5 kV, not over 121 kV / 4 ft. 0 in. (122 cm),
Over 121 kV, not over 140 kV / 4 ft. 6 in. (137 cm).