Control Panel Description
A
A - ON-OFF/Drain
power switch tur
turned on and the automatic drain cycle when tur
B - LCD
screen displays machine status: including temperatures, operation, heating and autoclean
functions such as, wait, and in-cycle.
TEMPERATURE DISPLAY
indicates water temperature and
displays operation codes for the operator. The minimum wash water temperature is 150°F/66°C.
The minimum/maximum final rinse temperature is 180-195°F/ 82-91°C.
WAIT INDICATOR
light illuminates during the initial fill and as the booster heats to the minimum
180°F/82°C. The indicator light goes out when 180°F/82°C is achieved.
C - DETERGENT PRIME SWITCH
when pressed, runs the detergent dispensing pump to prime the
pick-up hose during initial set-up and whenever the detergent supply container is changed.
D - START PUSH BUTTON
Pressing the START button initiates an automatic timed cycle and illuminates
the IN CYCLE light.
E
- PRESSURE GAUGE
indicates the final rinse water flowing pressure during the initial fill and
the automatic final rinse cycle. The proper pressure reading is 20-22 PSI. The pressure gauge
is located on the left side of the lower front panel.
10
0
30
20
PSI
60
50
40
PRESSURE
20-22 PSI
E
Fig. 18
B
C
D