4
|
BT80i Sound Sensor User’s Guide
Technical Specifications
Sensor kind
Analog, generates an output voltage
between -10
.. 10 V
Note:
When no sound is detected the output is 0 V.
Measurement ranges
Air pressure
Sound level
-45 .. 45 Pa (0.45 mbar )
50 .. 110 dB
Resolution using
12 bit AD converter
22 mPa (0.22
µ
bar)
Frequency range
50 Hz - 12000 Hz
Calibration function
p (Pa) = 4.5 * V
out
(V)
Current requirement
< 5 mA
Connection
IEEE1394 connector for BT-IEEE1394 sensor cable.
Sensor cable
not
delivered with the sensor.
Warranty:
The Sound sensor BT80i is warranted to be free from defects in materials and
workmanship for a period of 24 months from the date of purchase provided that it has
been used under normal laboratory conditions. This warranty does not apply if the
sensor has been damaged by accident or misuse.
Note:
This product is to be used for educational purposes only. It is not appropriate for
industrial, medical, research, or commercial applications.
Rev. 05
/03/2018