MODEL EST-44 Service and Parts Manual Rev. 2 .08A
Page
2
1. Specifications
1.1. EST- 44
WATER CONSUMPTION
PER RACK (FINAL RINSE)
.46 GAL.
.46 GAL.
PER HOUR (FINAL RINSE)
114 GAL.
114 GAL.
CONVEYOR SPEED
FEET PER MINUTE
6.75
6.75
OPERATING CAPACITY
RACKS PER HOUR (NSF rated)
249
249
OPERATING TEMPERATURE
WASH RECOMMENDED
140° - 150° F
150° - 160° F
PUMPED RINSE RECOMMENDED
140° - 150° F
150° - 160° F
FINAL RINSE RECOMMENDED
140° - 150° F
180° - 195° F
WATER REQUIREMENTS
INLET TEMPERATURE (MIN)
140° F
180° F
WATER INLET SIZE
1/2”
FINAL RINSE SIZE
1/2”
DRAIN SIZE
2”
FINAL RINSE PRESSURE
20 PSI
HEATERS
WASH HEATER
13.3 KW/240V(1 phase)
13KW/208V(3 phase)
RINSE HEATER
3KW/240V, 2.25KW/208V
MOTORS
WASH PUMP
1 HP
RINSE PUMP
1/3 HP
CONVEYOR
1/8 HP
DIMENSIONS
DEPTH
25-
1/8”
WIDTH
44”
HEIGHT
55 -
1/2”-56-1/2”
STANDARD TABLE HEIGHT
32 ½” adjusts to 34”
MAX CLEARANCE FOR DISHES
19”
VENTILATION REQUIREMENTS CFM
600 Total, 400 at exit, 200 at entrance
STANDARD RACKS
VOLTS
PHASE
AMPS
AMPS(Tall)
ELECTRICAL RATING
208
1
71
N/A
240
1
80
N/A
208
3
55
60.5
240
3
62.5
69
480
3
24
27
SHIPPING WEIGHT
662#
(300kg)
High temp
Low Temp
Summary of Contents for EST-44
Page 1: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 12: ......
Page 15: ......
Page 16: ......
Page 19: ......
Page 20: ......
Page 24: ......
Page 26: ......
Page 27: ......
Page 33: ......
Page 34: ......
Page 37: ......
Page 39: ......
Page 41: ......
Page 45: ......
Page 49: ......
Page 52: ......
Page 54: ......
Page 55: ......