2.2.11. (Optional) E-Temp Booster Heater
*
The Optional E-Temp Booster Heater can only be ordered with a dishwasher, already installed at
the factory; it
cannot
be installed in the field. The E-Temp Booster heater will be fully integrated
into the EST-
44 conveyors’ plumbing system. It will require its’ own power supply of 208 volts to
240 volts, in single-phase or three-phase. The unit can be specially ordered as a 480-volt unit, in
three-phase only; temperature is available in a 40° rise or 70° rise. The E-Temp Booster heater
contactor is located in the EST-44 Main Control Box (See item 7, page 6).
Note: E-Temp heater is shipped on the machine empty to prevent freezing. When machine
is powered up for the first time, the booster heater must be filled by pressing
and holding
rinse switch to prevent heater damage.
Note:
70° degree rise E-temp Booster Heater is only available in Three-Phase.
*
Electrical and plumbing connections must be made by a qualified person who will comply with all
available Federal, State, and Local Health, Electrical, Plumbing and Safety codes