3
Removal
- Remove the neck from the hollow wrist torch body.
- Pull the power pin out of the wire feeder and remove the liner.
- Unscrew the (3) buttonhead screws on the torch body cover.
- Slide off the torch body cover and sleeve and loosen the M4 screw on the cable connector.
- Pull the front of the cable assembly from the cable connector.
- Remove the cable assembly from the robot.
Power Pin
Cable Assembly
Cable Connector
Installation of New Cable Assembly
- Install the insulating disc by lining up the pin to the pin hole of the turning disk, and use the (4) M4 screws to tighten.
- Line up the torch body w/ spacer with the pin hole of the insulating disc and screw in the (4) M5 screws
that hold the torch body to the insulating disc.
- Slide the cable assembly through the robot arm. Do not connect the power pin.
- Push the front of the cable assembly into the torch body and tighten the M4 screw of the cable connector.
- Slide on the spacer sleeve over the torch body and spacer, then the torch body cover over the torch
body and tighten the (3) buttonhead screws.
- Install the liner through the power pin, and make sure the power pin is connected to the wire feeder properly.
(Tighten set screw if necessary.)
- Install the neck without consumables and cut the liner to the proper length as needed.
Cable Assembly Overview
-Installation & Removal of Cable Assembly-