ELECTRICAL COMPONENTS
Solenoid
2006 IQ Plus System Electric Vehicle Maintenance and Service Supplement
Page 13-9
13
5. Lift the solenoid (2) up and off of the component mounting plate.
Solenoid Installation
1. Mount solenoid (2) onto component mounting plate with screws (1)
2. Tighten screws (1) to 60 in-lb (6.8 N·m).
3. Using the wiring diagram, install the wires, washers, and nuts onto the large mounting posts. Tighten nuts
to 77 in-lb (8.7 N·m).
See Wiring Diagrams, Section 11, Page 11-2.
4. Install the blue/white and light blue wires onto the small terminals of the solenoid
5. Install speed controller cover.
See Installing the Speed Controller Cover on page 13-8.
6. Place the Tow/Run switch in the TOW position and connect the battery cables, positive (+) cable first.
Tighten battery terminals to 110 in-lb (12.4 N·m) and coat terminals with Battery Terminal Protector Spray
(CCI P/N 1014305) to minimize corrosion.
Figure 13-7 Solenoid
SOLENOID
2
1
TYPICAL
2 PLACES