Battery Charger, QuiQ™ – Electric Vehicles
1
2
20
Figure 27
Receptacle Fuse Link
RECEPTACLE FUSE LINK – POWERDRIVE 3 CHARGER VEHICLES
As an additional feature to protect the batteries and charging circuit from an overload, the electric vehicle is equipped
with a receptacle fuse link
(Figure 27)
. If the charger does not come on when the vehicle is placed on charge,
visually inspect the fuse link.
See following WARNING.
WARNING
• If the receptacle fuse link is blown, determine the source of the electrical problem and correct it before
replacing the fuse. Contact your nearest Club Car distributor/dealer.
BATTERY CHARGER, QuiQ™ – ELECTRIC VEHICLES
Electric vehicles shipped to the state of California use the Delta-Q QuiQ battery charger to meet CEC regulatory
requirements.
DANGER
• Battery – Explosive gases! Do not smoke. Keep sparks and flames away from the vehicle and service
area. Ventilate when charging or operating vehicle in an enclosed area. Wear a full face shield and
rubber gloves when working on or near batteries.
• The charging area must be ventilated. Hydrogen level in the air must never exceed 2%. The total
volume of air in the charging area must be changed five times per hour. Exhaust fans should be
located at the highest point of the roof. Contact a local HVAC engineer.
DANGER CONTINUED ON NEXT PAGE
Page 52
XRT 850 Electric and Gasoline Vehicle Owner’s Manual
Summary of Contents for 2007 XRT 850
Page 2: ......
Page 6: ...Warranties 70 Page 4 XRT 850 Electric and Gasoline Vehicle Owner s Manual...
Page 79: ......