1. Level Indicator 2. Cap 3. Plates
Maintain electrolyte level from at least 1/2 inch (13 mm) above
plates to 1/4 inch (6 mm) below level indicator.
17
Figure 27
Battery Electrolyte Level
BATTERY CHARGER – ELECTRIC VEHICLES
DANGER
• The charging area must be ventilated. Hydrogen level in the air must never exceed 2%. The total
volume of air in the charging area must be changed at least five times per hour. Exhaust fans should
be located at the highest point of the roof. Contact a local HVAC engineer.
• Do not charge the vehicle batteries with the vehicle covered or enclosed. Any enclosure or cover
should be removed or unzipped and pulled back when batteries are being charged. An accumulation
of hydrogen gas could result in an explosion.
WARNING
• Only trained technicians should repair or service the charger. Contact your nearest Club Car
distributor/dealer.
• Each charger should have its own dedicated 15 or 20 ampere separately protected (circuit breaker or
fuse) single phase branch circuit, in accordance with all applicable electrical codes for the location.
• Connect the charger AC supply cord to a properly grounded, three-wire outlet of the proper voltage
and frequency as shown on the charger.
• Do not use an adapter to plug the charger with a three-prong plug into a two-prong outlet. Improper
connection of the equipment-grounding conductor can result in a fire or an electrical shock.
WARNING CONTINUED ON NEXT PAGE
Page 48
Precedent Gold Standard Remanufactured Vehicle Owner’s Manual
Summary of Contents for 2 in 1 Series
Page 2: ......
Page 72: ...Warranties Page 70 Precedent Gold Standard Remanufactured Vehicle Owner s Manual...
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ...NOTES...
Page 78: ......
Page 79: ......
Page 80: ...Publication Part Number 103814501 Edition Code 0710E0613D 103814501...