background image

IMPORTANT:  These luminaires maintain a watertight seal between each other via an EPDM rubber washer (each 
luminaire is provided with one washer).  It is imperative that this joint be tightened prior to final tightening of the 
fasteners.  If fasteners are tightened first, it will be impossible to draw the two luminaires together properly and create a 
waterproof seal.  The slotted stainless-steel mounting tabs allow the fasteners to be partially installed while still allowing 
the movement required to properly tighten the waterproof joint between.  When this joint has been properly drawn 
together, the fasteners may be tightened.

1” long x 1/2” (trade size) galvanized 
electrical nipple and locknuts (to be 
provided by installing electrical 
contractor)

Place the ends of the luminaire together, and tighten the locknuts untill the two luminaires are drawn together very 
securely. When the EPDM washer is properly compressed, the gap between to two luminaire ends should be 
approximately 1/32”.

EPDM washer (provided by 
Cathode Lighting Systems)

conduit locknut

conduit locknut

Installing luminaires end to end

Page 4

8020 Queenair Drive
Gaithersburg, MD 20879
Ph: (800) 551-5012
Fax: (301) 963-3050
Email: [email protected]

ECLS Manual 6-08

c

2008 Cathode Lighting Systems 

stainless mounting tab

1/32” spacing between 
fixtures when locknuts 
are tightened securely, 
compressing the EPDM 
washer

Summary of Contents for ECLS

Page 1: ...08 c 2008 Cathode Lighting Systems Cathode Lighting Systems Inc 8020 Queenair Drive Gaithersburg MD 20879 Ph 800 551 5012 Fax 301 963 3050 Email Info CathodeLightingSystems com INSTALLATION MANUAL Mo...

Page 2: ...sible below the shoulder of the lens fastener This will allow the lens fastener to be moved up and out of the way to remove the lens 8020 Queenair Drive Gaithersburg MD 20879 Ph 800 551 5012 Fax 301 9...

Page 3: ...aire is designed to be securely fastened on each of its four corners Rubber sealing plug do not remove unless it is being replaced with a liquid tight fitting or being coupled to an adjacent luminaire...

Page 4: ...TACHING CONDUIT TO THE UNDERSIDE OF THE LUMINAIRE If it is required that the conduit penetration location be concealed a standard 7 8 hole may be drilled in the back of the luminaire making sure the h...

Page 5: ...r the fasteners may be tightened 1 long x 1 2 trade size galvanized electrical nipple and locknuts to be provided by installing electrical contractor Place the ends of the luminaire together and tight...

Page 6: ...Ph 800 551 5012 Fax 301 963 3050 Email Info CathodeLightingSystems com ECLS Manual 6 08 c 2008 Cathode Lighting Systems Ballasts are available either in 120 volt or 277 volt models Primary amperage i...

Page 7: ...sketed channel Correct End of lens sits evenly spaced within the gasket Incorrect End of lens is too close to the outside wall of the gasket channel Incorrect End of lens is too close to the inside wa...

Page 8: ...or spiraling effect Turn the luminaire off for five seconds and then turn off for two seconds Repeat this procedure 5 10 times The rolling or spiraling should stop If the lamp continues to roll or spi...