background image

1/8” to 3/16”

Receiving your shipment

Please follow the instructions below.  All shipments are F.O.B. Gaithersburg, MD. 
If any damage has occured, you must immediately alert the shipper so that a claim may
be filed. 

How to remove the polycarbonate lens

Loosen, (but do not remove) the screws which attach the two full-length retaining clips on each side of the luminaire.  The 
retaining clips can then be lifted up and tilted back from the luminaire allowing the tethered lens to be removed. 
Approximately 1/8” - 3/16” of the screw thread will be visible below the shoulder of the lens fastener.  This will allow the 
lens fastener to be moved up and out of the way to remove the lens.  

8020 Queenair Drive
Gaithersburg, MD 20879
Ph: (800) 551-5012
Fax: (301) 963-3050
Email: [email protected]

ECLS Manual 6-08

c

2008 Cathode Lighting Systems 

1) Remove the luminaire from its packaging.

IMPORTANT:  Please take all precautions to ensure that no water or moisture enters this luminaire during 
installation.  These luminaires are IP65 rated, and are water, and vapor tight.  Any moisture that enters the 
luminaire while the lens is removed, will be trapped inside after reinstallation of the lens.  It is strongly 
advised to install this product only when dry weather conditions prevail.

Page 1

Summary of Contents for ECLS

Page 1: ...08 c 2008 Cathode Lighting Systems Cathode Lighting Systems Inc 8020 Queenair Drive Gaithersburg MD 20879 Ph 800 551 5012 Fax 301 963 3050 Email Info CathodeLightingSystems com INSTALLATION MANUAL Mo...

Page 2: ...sible below the shoulder of the lens fastener This will allow the lens fastener to be moved up and out of the way to remove the lens 8020 Queenair Drive Gaithersburg MD 20879 Ph 800 551 5012 Fax 301 9...

Page 3: ...aire is designed to be securely fastened on each of its four corners Rubber sealing plug do not remove unless it is being replaced with a liquid tight fitting or being coupled to an adjacent luminaire...

Page 4: ...TACHING CONDUIT TO THE UNDERSIDE OF THE LUMINAIRE If it is required that the conduit penetration location be concealed a standard 7 8 hole may be drilled in the back of the luminaire making sure the h...

Page 5: ...r the fasteners may be tightened 1 long x 1 2 trade size galvanized electrical nipple and locknuts to be provided by installing electrical contractor Place the ends of the luminaire together and tight...

Page 6: ...Ph 800 551 5012 Fax 301 963 3050 Email Info CathodeLightingSystems com ECLS Manual 6 08 c 2008 Cathode Lighting Systems Ballasts are available either in 120 volt or 277 volt models Primary amperage i...

Page 7: ...sketed channel Correct End of lens sits evenly spaced within the gasket Incorrect End of lens is too close to the outside wall of the gasket channel Incorrect End of lens is too close to the inside wa...

Page 8: ...or spiraling effect Turn the luminaire off for five seconds and then turn off for two seconds Repeat this procedure 5 10 times The rolling or spiraling should stop If the lamp continues to roll or spi...