CDPM Digital Paging Microphone
Setup And Installation Guide
CLOUD ELECTRONICS LIMITED
Table 8.1: Default Jumper Settings
When removing jumpers we recommend that the link remain connected to one leg of the header, to
prevent loss of the link.
When making internal adjustments please ensure that you:
• Disconnect power to the unit before deconstructing. Where the microphone is powered from
another unit, this will mean removing the connection to that unit. For access terminal block
connections, this is best achieved at the mixer end of the connection.
• Only reassemble the unit using the original screws or screws identical to the originals.
Fig 8.1: Jumper locations on CDPM main PCB
J1
+1 to Chime Select
ON
J2
+2 to Chime Select
OFF
J3
+4 to Chime Select
OFF
J4
Terminate Buss
ON
J5
Chime On/Off
ON
J6
Internal Chime On/Off
ON
J7
NVM Reset
OFF
J8
Priority
OFF
J9
Group Lock
OFF
J10
Auto Zone Reset
ON
J11
+8 to Bank Offset
OFF
J12
+4 to Bank Offset
OFF
J13
+2 to Bank Offset
OFF
J14
+1 to Bank Offset
OFF
10