underlying software) and application software upgrades (system software applications). Select "tools" on the 

main interface > "software upgrade" > "software", the pop-up dialog box, as shown in image 4-33: 

 

Image  4-33  Application software upgrade

 

To find the Bin upgrade file path in the upgrade file drop-down list, click 

 the upgrade 

progress bar shows 100% that means the application software upgrade successfully, pop-up upgrade 

prompted success dialog box, click OK to restart the reader, as shown in image 4-34. 

 

Image  4-34  Software upgrade successfully

 

The process of the application of the base band software is the same as that of the application software. 

Summary of Contents for CL7206C2

Page 1: ...CL7206C2 Four Port Fixed RFID Reader User Manual V1 0 Shenzhen Clou IOT Technologies Co Ltd...

Page 2: ...Welcome to be user of CLOU RFID products Thanks for choosing CLOU s Four Port Fixed RFID Reader CL7206C2 We believe our device will bring convenience for your work...

Page 3: ...play 8 2 4 Sketch map of interfaces 9 2 4 1 Interface description 9 2 4 2 Sketch map of I O interface 9 2 4 3 Schematic diagram of USB interface 11 2 4 4 Description of feeder line optional 11 2 4 5 N...

Page 4: ...der 16 4 5 1 1 Serial communication connection 16 4 5 1 2 Network port communication connection 17 4 5 1 3 RS485 communication connection 18 4 5 1 4 USB communication connection 19 4 5 2 Data display...

Page 5: ...uto idle configuration 30 4 5 12 GPI O configuration 30 4 5 13 Advanced configuration 32 4 5 14 Tools 33 5 Common failures 35 5 1 Daily maintenance 35 5 2 Common failure analysis and solution 35 6 Pac...

Page 6: ...te rate strong anti interference ability good protection performance and easy installation 1 2 Main function and technical features 1 2 1 Main function Protocol support ISO18000 6C 6B standard Built i...

Page 7: ...ironment Channel bandwidth 200 KHz RS232 serial communication rate 115200bps default 19200 bps 9600bps RS485 interface communication rate 115200bps default 19200 bps 9600bps Support Weigand 26 34 66 i...

Page 8: ...of CL7206C2 Volume of four port fixed rfid reader CL7206C2 324mm 225mm 62mm accessories excluded 2 2 Weight About 2 6kg accessories excluded 2 3 Illustration of LED display Image2 2 Sketch map of rea...

Page 9: ...ates antenna 4 is working Status Status indicator Flashing indicates recognition to tags POWER Power indicator Keep bright indicates power supply working normally 2 4 Sketch map of interfaces Image 2...

Page 10: ...output port OUT_R2 3 Relay 3 output port OUT_R3 4 Relay 4 output port OUT_R4 5 optocoupler 1 external signal input positive IO_INPUT1 6 optocoupler 3 external signal input positive IO_INPUT3 7 optoco...

Page 11: ...software online upgrade as shown in figure 2 5 USB interface 2 USB communications serial port and network communication all in one as shown in figure 2 5 USB communication interface Image 2 5 schemat...

Page 12: ...ce deterioration on the read and write because of the emission signal and the received echo signal s attenuation 2 4 5 Network application connection diagram Network interface used for long distance h...

Page 13: ...4 When installing several readers the antenna position and the antenna spacing should be appropriate to avoid interference with each other 3 2 Installation conditions Before installing the reader plea...

Page 14: ...RJ45 network port used for long distance communication less than 80m connect PC with extend cable 3 4 Device installation The reading and writing range of the reader depends on the onsite application...

Page 15: ...writer start up hear drop buzzer sound 4 2 Demo software application environment The software environment Windows 2000 Service Pack 3 Windows Server 2003 Windows XP Service Pack 2 Windows 7 system Th...

Page 16: ...gray means reader is not connected in the connecting reader option list select communication mode serial connection connection parameters select COM choose PC serial number communication rate select 1...

Page 17: ...munication mode TCP connection in the connect reader option list connect parameter input reader IP default 192 168 1 116 enter the communication port number default 9090 and click OK button as shown i...

Page 18: ...s connected on PC Image 4 4 Settings of reader 4 5 1 3 RS485 communication connection Select the communication mode in the connect to the reader option 485 connection serial port connect parameter sel...

Page 19: ...t in the connect reader option list connect parameter select COM the USB serial number detected by PC the communication rate is selected 115200 the default value and click OK button as shown in image...

Page 20: ...SI Signal Intensity 4 5 2 1 Read EPC Click the button the data display area will display the current read EPC data EPC display as hexadecimal character string use the word as length unit 1 word 2 byte...

Page 21: ...the user area select to read the tag user area data use the word as the starting address and read length unit Read the reserved area select to read the tag retains data use the word as the starting a...

Page 22: ...age 4 13 6B Tag custom configurations 4 5 2 4 Stop read Click button stop all read and write operations 4 5 3 Write data 4 5 3 1 Write EPC data Click button and pop up dialog box as shown in image 4 1...

Page 23: ...C data Select a label data contains TID information has been read fill in the EPC data 16 hex string click OK 4 5 3 2 Write user data Click button and pop up dialog box as shown in image 4 16 Image 4...

Page 24: ...n in image 4 17 Image 4 17 Custom tag action 1 Select a tag data that has been read 2 Click the custom operation button 3 Take detailed action to write lock destroy tag according to the reader protoco...

Page 25: ...e it will connect to the PC side automatically 4 5 5 Antenna enable configuration Select configuration on the DEMO main interface senior reader configuration then pop up dialog box as shown in image 4...

Page 26: ...ader then pop up dialog box as shown in image 4 21 Image 4 21 Base band parameter configuration Changing the base band parameter configuration can change the actual effect of the read and write can be...

Page 27: ...ect the corresponding antenna port external antenna connected select the appropriate power values from the power list click Configure pop up the configuration of the success of the dialog box click OK...

Page 28: ...mage 4 25 in the working band drop down list click the Settings select single frequency points from the left frequency list box see Image 4 24 then click the button right into the list box and then cl...

Page 29: ...n list in image 4 24 4 5 10 Label filtering Select configuration on the main interface RFID configuration label filter then pop up dialog box as shown in image 4 26 Image 4 26 label filtering Filterin...

Page 30: ...dn t identify the tags for three times continuously then the reader automatically enter a period of idle state to save power consumption the reader re enter the card reader automatically after idle ti...

Page 31: ...t Trigger execution instruction select the mode from the drop down list Trigger stop condition select the mode from the drop down list Description when the start condition is satisfied the reader will...

Page 32: ...e open state and select the corresponding communication format and transmission data content click on the configuration to determine Weigand port Parameter configuration includes Weigand 26 Weigand 34...

Page 33: ...export Select tools on the main interface data export form XLS in the pop up dialog box as shown in image 4 32 select the required export file save path Image 4 32 Data export Read the tag data to sup...

Page 34: ...e upgrade To find the Bin upgrade file path in the upgrade file drop down list click the upgrade progress bar shows 100 that means the application software upgrade successfully pop up upgrade prompted...

Page 35: ...ight failed when power on Check whether the communication is normal please contact customer service if it s not normal The serial port unable to connect Check if the serial cable is not connected or c...

Page 36: ...ck if the label is damaged Check if the label is placed in the reader s valid reading and writing range Check if the electromagnetic interference between the reader and the other device For the proble...

Page 37: ...g box and the packing material should be kept properly after unpack Besides of the device in the box accessories equipped with the reader are also included in please check the product packing list to...

Page 38: ...d 20350000000195 1 unit Included 4 Network cable 20350000000188 1 unit Included 5 RS232 blackcable 20351000000478 1 pcs Included 6 USB cable 20351000000036 1 pcs Included 7 9dBi circularly polarized a...

Page 39: ...of circuits without given notifications Thus the real product may be not in accordance with this manual Generally we will provide timely amendments to this manual If it s not provided timely please co...

Page 40: ...with each device please keep it to enjoy the service 1 Products can replace free under conditions within one month after sale in the precondition of normal operation without repairing 2 Free maintenan...

Reviews: