Image 4-25 Frequency Band selection
Note:
The purpose of setting up the "automatic" is to avoid the interference of the external signal and select the
fast frequency hopping. The default configuration for general application is automatically (as shown red mark
dropdown list in image 4-24).
4.5.10 Label filtering
Select "configuration" on the main interface > "RFID configuration" > "label filter", then pop-up dialog box, as
shown in image 4-26:
Image 4-26 label filtering
Filtering time: indicates that the same label content within a specified period of time within a read card
instruction is only uploaded once, 0~65535, and time units: 10ms.
RSSI threshold: When label RSSI value small than the threshold value, the label data will not be uploaded