Flushing
Press either elbow pad whilst standing
for conventional flush.
Washing
Press elbow pad whilst seated and hold
down for approximately 10-15 seconds,
flushing and warm water washing will
then take place.
Drying
Warm air drying automatically follows
when elbow pad is released.
Further notes
•
No permanent hand rails or other obstructions
should be fitted across the front or top of the unit.
The outer casing has to be pulled upwards and
forward to remove for servicing purposes.
•
Unit not rated for altitude. 2000m is the
maximum.
•
This application requires an earth connection.
•
Environmental conditions – operating ambient
room temperature maximum = 40
°
C.
Environmental conditions
The Closomat toilet is rated to IPX4 and can be
installed and operated within a typical shower/toilet
room.
Infill panel
The infill panel specifications are printed on page 11.
Classification
Low Voltage Directive EN 60335-2-84.
Cleaning information
•
The use of bleach products is not advised due
to the exposed stainless metal parts associated
with the washing device. (tarnishing may occur).
•
The Closomat toilet washing device is designed
to self cleanse during and after every use.
Normal cleansing of the bowl and outer covers
is required.
Maintenance and frequency of
serviceable parts
•
The Closomat toilet is self-sufficient but it is
recommended that a competent experienced
Service Engineer carry out a safety check and
an annual service of the internal workings,
to extend the Closomat’s life.
Risk associated with the waste of
equipment after service life
•
At the stage the unit is not repairable it can
be discarded to any appropriate recyclable
plant. There are no immediate risks to the
environment.
User guide