background image

  Safe working load: 190kg/30st

 Overall dimensions: 869mm high x 451mm wide x 730mm deep

Key / Installation guide:

1.  Determine unit height as standard or with optional points  (P)
2.  Locate floor & wall template jig to plan positions  (J)
3.  Locate waste pipe / soil position  (S)
4.  Locate cold water supply  (W)
5.  Locate electrical supply  (E)
6.  Use floor template jig for fixing frame (J)

Water services

Supplied with 15mm 
Stainless steel braided 
outer, EDM inner WRAS
approved flexible hose. 
(Please refer to page 2,
water services prior to 
installation)

  

Waste details

Pan has a horizontal 
spigot standard 100mm 
diameter outlet, suitable 
for standard pan 
connection fittings.

D

Rear wall fixing

 

Position 25mm to RH of 
the centreline. 810mm 
from the floor.

R

Rear floor fixing (2No) 

(Standards Installations)

Position on the floor 
102mm from the rear wall. 
119.5mm to each side of 
the centreline.

F

Front floor fixing (2No) 

(When using Support Arms)

Position on the floor 327mm 
from the rear wall. 119.5mm 
to each side of the 
centreline.

S

W

S

E

D

S

F

R

Floor & Wall 

Templates

Located in

Document Box

J

J

Electrical services

Supplied with 1000mm long,
three core (live/neutral/earth)
insulated 3183Y-1-white
control flex-cable, rated to
220-240V, 4.5A-4.9A. 
(Please refer to page 2,
electrical services prior
to installation)

E

 

Palma Vita planning data 
and service requirements

4

www.closomat.co.uk

Tel: +44 0800 374 076

PALMA VITA

220-240V, 50Hz

4.5A-49A IPX4

10A

190kg

30st

Summary of Contents for Palma Vita

Page 1: ...Closomat Palma Vita installation user guide...

Page 2: ...introduced by signal words which express the extent of the hazard risk In order to prevent accidents personal injury property damage and guarantee maximum user safety follow the safety instructions w...

Page 3: ...ed within a typical shower toilet room Infill panel The infill panel specifications are printed on page 11 Classification Low Voltage Directive EN 60335 2 84 Cleaning information The use of bleach pro...

Page 4: ...for standard pan connection fittings D Rear wall fixing Position 25mm to RH of the centreline 810mm from the floor R Rear floor fixing 2No Standards Installations Position on the floor 102mm from the...

Page 5: ...er completely but do not remove it IMPORTANT Please retain all packaging until the installation is complete Protect all floor surfaces when handling the Closomat DO NOT slide the Closomat across the f...

Page 6: ...ion the Closomat and place all four anchor blocks in place 15 Secure the Closomat to the floor using all four fixing points use suitable fixing for the application Adhesives are not allowed to be used...

Page 7: ...rm to hold in this extended position arrow Run wash cycle to purge Once wash is constant remove tool and allow the douche arm to retract 2 Allow approximately 5 minutes for the water to heat in the bo...

Page 8: ...bow pads 8 Replace the seat by locating the seat pivots into the seat hulls fixed to the pan press the seat firmly to secure its position 7 Push in the seat buffer on the cistern cover 4 Replace ciste...

Page 9: ...it the side panel and screw covers on completion 1 Using the template provided locate mark and drill four holes for the plinth in the floor to best suit the intended fixings to be used for the applica...

Page 10: ...armrest is moved Important Ensure Belville Washer is assembled correctly with the dome towards the bolt head Hole diameter 76mm minimum 78mm maximum Measure 367mm from rear of unit to centre of arm fi...

Page 11: ...installation where pipe work inhibits the Closomat toilet from being located against the wall The infill panel is available in thickness sizes 25mm 50mm and 75mm The infill panel is 100mm taller than...

Page 12: ...losomat co uk closomat co uk British manufacturing British design and development British customer support We reserve the right to make modifications as a result of ongoing adjustments and further dev...

Reviews: