V1.4 2019-09
Page 21 of 35
7
Configuring TIM-1000
There is not a lot that needs to be configured for TIM-1000. The only things that can be configured
are:
•
Tracking ON/OFF
•
Noise Suppression ON/OFF
•
APT
•
Light Ring Colour
•
EQ
•
IP settings
•
Date and Time
•
Software upgrade
•
Passwords
TIM-1000 as shipped from the factory is configured to accept DHCP. This means that the control port
when plugged into the network will receive its IP address from a DHCP server and when the PoE port
is plugged into the Dante network, it would negotiate a link local address.
If the IP addresses need to be changed, then the Control IP address can be changed by going into the
Advanced tab of the Web GUI and setting a static IP address. The IP address of the Dante port cannot
be changed from the Web GUI – this can only be changed through Dante Controller.
Date and Time can be set through the Advanced tab. If the NTP server’s IP address is 0.0.0.0 (i.e. set
as an invalid address), then the date and time fields can be used to set the time. If the NTP server
address is defined as a valid IP address, then TIM-1000 will attempt to contact the appropriate server
to look up and set the time.
If the passwords of the Home and/or Advanced tab are forgotten, not available or have been lost, then
it’s possible to perform a system reset. See section on Reset Switch on how to perform this action.
Software upgrade is a simple process and can be performed in one of two ways:
1.
By dragging and dropping the software “tar” file that is supplied into the software upgrade
box on the Advanced tab
2.
Clicking into the software upgrade box. This action will create a pop up on the window through
which you can navigate to the appropriate area where the “tar” file resides. Select the “tar”
file and click Open.
Once the software upgrade starts, TIM-1000 will lose connection to the network during the process
and the web GUI will become unresponsive. The whole upgrade process should take no longer than 5
minutes. If the web GUI does not refresh, it will need to be connected again.
It’s important to note that any changes (apart from Control IP address) made on the Advanced tab will
require clicking on the “Reboot and apply ALL settings” button. When this is done, TIM-1000 may lose
contact with the server, but depending upon the network configuration the GUI should refresh after
a short while.