32
8. Upgrading the Firmware
You can easily upgrade your CG-410 firmware by updating the new version of firmware through the
network or a serial interface.
8.1. Upgrading the Firmware by FTP
When your CG-410 is connected to the network and it is accessible by its IP address, you can
upgrade its firmware by FTP, the fastest way to upgrade. However, FTP cannot be used when your
CG-410 is in an abnormal state or when it is not connected to the network.
The following example shows how a command line FTP client is used to upload a new firmware (“CG-
410.fls”) to the CG-410. Its IP address is 192.168.0.36. Enter “admin” as the user name and type in
the password that is set in the VoIP configuration web page of the CG-410. The default password is
“0000.”
The system will reboot automatically when upgrading the firmware by FTP is completed.
C:\> ftp 192.168.0.36
Connected to 192.168.0.36.
220 Precise/RTCS FTP Ready
User (192.168.0.36:(none)): admin
331 Password required for admin
Password:
Type a password (4-digit number).
230 Logged in
ftp> bin
200 Type OK
ftp> put CG-410.fls flash
200 Port command okay
150 Opening data connection for STOR (192.168.0.14,1161)
226 File received OK – 1053136 bytes in 10.640 sec
ftp: 1053136 bytes sent in 10.55Seconds 99.82Kbytes/sec.