![Clinton AS-895E Service Manual Download Page 9](http://html.mh-extra.com/html/clinton/as-895e/as-895e_service-manual_2625271009.webp)
4-2
®
ML895E-22
TABLE 4-1
PARAMETER
DESCRIPTION
DEFAULT
RANGE
SPEED GROUP
RPM
RPM
MINIMUM
SLOW STRT
VENT.SPD
First speed when pedal is moved forward.
Initial speed at start of cycle (after trim).
This speed is maintained for No. of stitches set
by soft start count parameter.
Speed motor runs while venturi is active
180
500
2000
80-250
150-1000
100-9000
TIMER GROUP
MS
MS
STRT DEL
VENT TIME
WASTE REM
CUT TIME
STACKER
Delays machine start to allow presser foot to
drop.
Delays venturi shut off after stop.
Waste removal turned on in the seam when this
function is selected.
Cutter on time or pulse length
Stacker on time
120
500
80
80
80
0-500
10-2500
10-1000
10-250
10-1000
COUNTER GROUP
STITCHES
STITCHES
SOFTST
FRNT.CNT
END CNT
WASTE REM
Number of stitches sewn at soft start speed
after trim (EOC).
Number of stitches with venturi on and first cut if
enabled after eye is covered.
Number of stitches with venturi on and end cut if
enabled after eye is uncovered.
Number of stitches with venturi on in the seam if
the waste removal function is selected.
3
3
3
3
1-25
1-25
1-25
1-25
TOGGLE SWITCHES
PF/SEAM
PF/EOC
SOFT STRT
HEEL 2
POSITION
TREADLE
START EYE
Pr. Ft. up or down in seam, treadle neutral.
Pr. Ft. up or down after trim, treadle neutral.
Used to turn soft strt "on" or "off".
If on, needle up. If off footlifter up with heel 2.
Selects the needle position in the seam to UP
or DOWN.
Neutral: Position before cycle starts
Continue: Cycle starts without releasing treadle
Uncov: Cycle starts independent of eye
Covered: Cycle starts only if eye is covered
DOWN
DOWN
OFF
ON
DOWN
NEUTRAL
UNCOVERED
UP/DOWN
UP/DOWN
ON/OFF
ON/OFF
UP/DOWN
NEUTRAL/
CONTINUE
COVERED/
UNCOVERED