![Clinton AS-895E Service Manual Download Page 7](http://html.mh-extra.com/html/clinton/as-895e/as-895e_service-manual_2625271007.webp)
SYNCHRONIZER TIMING
Turn the power off before making synchronizer adjustments. Refer to figure below for all adjust-
ments and perform the steps below to time the synchronizer.
1. Remove cover from synchronizer, then loosen the disc locking screw.
2. Rotate the handwheel so that the needle is at its highest position.
3. Rotate the UP sensor disc until the notch is centered in the photo interrupter module.
4. Rotate the down sensor disc until the notch is centered in the photo interrupter module.
5. Rotate the trim disc until the notch is centered in the photo interrupter module.
6. Tighten the disc locking screw and replace the cover.
NOTE:
After power is turned on a fine adjustment may be necessary and can be made by
positioning the needle under power and noting the actual needle UP and needle DOWN
stopping positions. If any of the positions are not correct, readjust the appropriate disc.